Mounting
Rear mounting – shaft diameters up to 20 mm
20
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5.2
Rear mounting – shaft diameters up to 20 mm
2
1
5
3
4
2.5
1.4...1.5 Nm
0.6…0.8 Nm
0°
Fig. 7: Rear mounting – shaft diameters up to
20 mm
Fig. 8: Zero point default value
1. Push the encoder sensor – with the rear to the shaft – onto the shaft and fasten with three
screws.
2. Mounting aid for optimum alignment of the positioning element.
3. Push the positioning element onto the shaft and align to the required position of the zero
point.
(factory setting for 0°: yellow arrow on the positioning element pointing to the black mark
on the sensor, see figure “Zero point default value”).
4. Fasten clamp fitting of the positioning element with hexagon spanner.
5. Remove mounting aid.
Optional: use protecting ring and SP1-QR24 aluminum shield plate.