V01.01 | 2022/03
17
Parameter
Meaning
Two Value Teach apply
The two-value teach-in from teach point 1 and teach point 2 is used. The
arithmetic average value of the two teach points is set as a switching point.
Dynamic Teach start
The dynamic teach-in is started. All objects that pass the sensor are measured.
The highest and lowest value of the object is determined. The arithmetic average
value is formed from the two values. The LEDs flash at a frequency of 10 Hz dur-
ing the operation. The teach-in is performed until the teach-in is stopped via
Dy-
namic Teach stop
.
Dynamic Teach stop
The dynamic teach-in is stopped. The arithmetic average value of the two teach
points is set as a switching point.
SP1 teach point status
It is possible to view at
SP1 teach point status
whether the current teach-in
operation was successful.
Teach cancel
The current teach-in operation is aborted and all teach points are set to zero.