Service Procedures
13
5.2.6 Door
Microswitch
1) Remove back panel.
2) Remove wires from switch.
3) Remove switch.
4) Check adjustment when new switch fitted.
5.2.5 Overtemp
1) Remove back panel.
2) Remove wires from overtemp.
3) Unhook back of phial from holder inside oven.
5) Pull phial towards back of oven to remove from
front holder.
6)
Remove phial through back of oven.
7) Undo the two screws securing the overtemp to the
base panel.
8) To install new overtemp feed capillary and phial
through oven cavity.
9) Push phial through front holder and then locate
rear of phial into back holder.
10) Secure overtemp in position.
Unhook phial
Phial Holder Detail
5.2.7 Fan
Motor
1) Remove Baffle plate.
2) Undo fan blade securing nut clockwise to undo.
(13mm)
Nut
3) Remove back panel.
4) Remove wires from fan motor.
5) Undo fan motor securing screws.
Fan Motor Securing Screws
Remove
screws