TurboChef Technologies, Inc. C Series
8-4
Heater Circuit Defective Messages
SELF TEST (STEST)
WHILE COOKING
(WARMING UP)
CAUSE
CORRECTIVE ACTION
THERMO OPEN
THERMO OPEN
HX Thermocouple amplifier
indicates open, (999
°
)."or"
CC Thermocouple amplifier
indicates open
1. Check Thermocouple connections on
I/O board connector (See I/O board
section for details) are not loose or
intermittently making contact with
mating connector.
2. Replace thermocouple.
HX RISE LOW
HX RISE LOW
1) During the warm up cycle if a
14
°
F rise is not detected within 5
minutes of initial warm-up, then
the controller displays "HX RISE
LOW".
2) HX Temperature failed to rise
14
°
F in 30 seconds during the
self-test mode.
1.
Check main internal circuit breaker.
If tripped, check the following
operation:
a) Interlock switches (Chapter 7)
b) Magnetron transformer (Page 9-8)
c) Hi-limit switch (See Figure 8-2)
2.
Check heater fuse (F3). If fuse is
blown check for short to chassis on
all heater wires.
3.
Check input current on heater
wires. (See Page 8-3)
4.
Check operation of the heater
relay. (See Page 8-3)
5.
Check blower operation (Page 8-9)
6.
Check crimp connections on
controller.
7.
Check HX Thermocouple.
LOW COOK TMP
(F3 LOW TEMP)
CC (Cooking Chamber)
temperature has dropped more
than 84
°
F (47
°
C) or more below
cook set point after 5 seconds or
more into cook cycle.
1.
Check main internal circuit breaker.
If tripped, check the following
operation:
a) Interlock switches (Chapter 7)
b) Magnetron transformer (Page 9-8)
c) Hi-limit switch. See Figure 8-2.
2.
Check blower operation. (Chapter
8-9)
3.
Check CC Thermocouple circuitry.
4.
Check Catalytic Converter (Page
8-2)
5.
Check debris catcher (pepperoni
catcher). See Figure 8-2
6.
Verify cooking chamber top air
nozzle holes are not clogged.
7.
Open door and run blower from 0%
to 100% and verify blower is
working properly (Air pressure).
8.
Verify oven software is greater
than Revision S (C3AD S).
Summary of Contents for C3/C
Page 2: ......
Page 3: ...TurboChef Technologies Inc C3 This page intentionally left blank ...
Page 4: ...TurboChef Technologies Inc This page intentionally left blank ...
Page 12: ...vi SAVE THESE INSTRUCTIONS ...
Page 14: ......
Page 15: ...CHAPTER 1 INSTALLATION SPECS ...
Page 18: ......
Page 19: ...CHAPTER 2 CLEANING OPERATING ...
Page 21: ...CHAPTER 3 THEORY OF OPERATION ...
Page 27: ...CHAPTER 4 FAULT CODES ...
Page 30: ......
Page 31: ...CHAPTER 5 TEST ...
Page 35: ...CHAPTER 6 ELECTRICAL CONTROLS SYSTEM ...
Page 45: ...CHAPTER 7 COOK DOOR ASSEMBLY ...
Page 52: ......
Page 53: ...Cook Door 7 9 Figure 7 58 Interlock Switch Adjustment ...
Page 56: ...TurboChef Technologies Inc C Series 7 12 FIGURE 7 6a C3 C C3 Cmulti Left Side ...
Page 64: ...TurboChef Technologies Inc C Series 7 21 Figure 7 9 C3 AB and C3Multi Door Assembly ...
Page 66: ...CHAPTER 8 CONVECTION CIRCUIT ...
Page 67: ......
Page 74: ......
Page 83: ...This page intentionally left blank ...
Page 84: ......
Page 85: ...CHAPTER 9 MICROWAVE CIRCUIT ...
Page 88: ...TurboChef Technologies Inc C Series 9 4 ...
Page 91: ......
Page 94: ......
Page 97: ......
Page 98: ...TurboChef Technologies Inc C Series 9 11 Waveguide Components Figure 9 6 Waveguide Assy ...
Page 101: ...CHAPTER 10 I O Board Schematics ...
Page 102: ...TurboChef Technologies Inc C Series 10 2 ...
Page 103: ...10 5 ...