Alarms
Press the
Menu
key in the home page.
Use the arrows
to select Advanced Set Up.
Press
OK
key.
Use the arrows
to select the item to be set.
Use keys
to increase or decrease the value and change the item
conditions. Press
exit
to save and exit.
Set Op er ation
Sel ectabl e Parameter s
Hourmeter Fan
Enabling the fan hour meter.
Connect the fan filter remote switch to
terminals 18_19 connector P9, to count
actual suction working hours
Replace Filters
Enter the number of working hours desired
to trigger the filtering element replacement
alarm (sleeves/cartridges), the alarm is
only generated if the fan hour meter is
enabled and the fan remote switch
connected to terminals 18_19 on connector
P9 on the electronic board.
Calibration / Test
Press the
Menu
key in the home page.
Use the arrows
to select Calibration / Test.
Press
OK
key.
Use the arrows
to select the item to be set.
Use keys
to increase or decrease the value and change the item
conditions. Press
exit
to save and exit.
Set Op er ation
Sel ectabl e Parameter s
No. Valve (+/- = ON) Activation
Press the keys
to manually start
the solenoid valves connected to the
electronic board in sequence.