U s e   A n d   M a i n t e n a n c e   I n s t r u c t i o n s

 

S e q u e n c e r   E 7 T   1 6   O u t p u t   C h a n n e l s

 

 

I n M n     S E 7 T  
e n     R e v . 0 0  

T U R B O   S r l

    D u s t   F i l t e r   C o m p o n e n t s  

V i a   P o   3 3 / 3 5   2 0 8 1 1   C e s a n o   M a d e r n o   ( M B )   I t a l y     T e l   + + 3 9   0 3 6 2   5 7 4 0 2 4     F a x   + + 3 9   0 3 6 2   5 7 4 0 9 2  

1 3  

 

Alarms 

Press the 

Menu

 key in the home page. 

Use the arrows  

  to select Advanced Set Up. 

Press 

OK

 key. 

Use the arrows  

  to select the item to be set. 

Use keys  

  to increase or decrease the value and change the item 

conditions. Press 

exit

 to save and exit. 

 

Set Op er ation 

Sel ectabl e Parameter s 

 

Hourmeter Fan 

Enabling the fan hour meter. 

Connect the fan filter remote switch to 

terminals 18_19 connector P9, to count 

actual suction working hours 

Replace Filters 

Enter the number of working hours desired 

to trigger the filtering element replacement 

alarm (sleeves/cartridges), the alarm is 

only generated if the fan hour meter is 

enabled and the fan remote switch 

connected to terminals 18_19 on connector 

P9 on the electronic board. 

Calibration / Test 

Press the 

Menu

 key in the home page. 

Use the arrows  

  to select Calibration / Test. 

Press 

OK

 key. 

Use the arrows  

  to select the item to be set. 

Use keys  

  to increase or decrease the value and change the item 

conditions. Press 

exit

 to save and exit. 

 

Set Op er ation 

Sel ectabl e Parameter s 

 

No. Valve (+/- = ON) Activation 

Press the keys  

  to manually start 

the solenoid valves connected to the 

electronic board in sequence. 

 
 
 
 
 
 
 
 

Summary of Contents for E7T

Page 1: ...hannels I n Mn SE 7T en Rev 00 TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 1 Se...

Page 2: ...____________________________________________________________ 13 Counters ____________________________________________________________________________ 14 Tribo Electric Probe __________________________...

Page 3: ...monitor where the following can be read at any time running solenoid valves time remaining for next air jet start the signalling of any alarms Interface menu available in five languages Operating mode...

Page 4: ...or Solenoid 115 Vac 50 60 Hz 10 230 Vac 50 60 Hz 10 24 Vac 10 24 Vdc 10 Inputs from 4 to 20mA x 1 Power Consumption 28 Watts Maximum Load Alarm Relays 3 Normally Closed Display Graphic LCD Backlit Mon...

Page 5: ...SE 7T en Rev 00 TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 5 Dimensions And Me...

Page 6: ...ity The electrical supply of the unit must be protected by a differential switch 230Vac 30mA and a bipolar magneto thermic 230Vac 10A positioned in a place easily accessible Before working on the equi...

Page 7: ...s cable diameter minimum of 4mm and a maximum of 8mm with clamping nut by 19mm Any use not described in this user instruction manual or incorrect use of the device may cause damage to the device or to...

Page 8: ...M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn SE7 T Rev 0 0 en Electrical Connections To connect the wires to the E7T control unit remove the cover panel t...

Page 9: ...SE 7T en Rev 00 TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 9 Jumper Configurat...

Page 10: ...s to settings it is used as RESET in the event of alarms Keys Increase and decrease the values manually start valves in Test mode used to scroll any alarms The S key allows to start stop the activatio...

Page 11: ...2 5 7 4 0 9 2 11 Menu Layout Basic Settings Press the Menu key in the main screen Use the arrows to select Main Set Up Press OK key Use the arrows to select the item to be set Use keys to increase or...

Page 12: ...the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters Cleaning Fan off Number of complete cleans with fan off for the number of connected solenoid va...

Page 13: ...Connect the fan filter remote switch to terminals 18_19 connector P9 to count actual suction working hours Replace Filters Enter the number of working hours desired to trigger the filtering element re...

Page 14: ...ters Press OK key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters...

Page 15: ...of 0 5 Sec 300 Threshold Alarm 0 01 mg m 1500 Time Alarm Recognition Multiple of 0 5 Sec 60 Threshold Peak 0 01 mg m 3000 Time Recognition Peak Multiple of 0 5 Sec 10 Reference Emissions 0 01 mg m 500...

Page 16: ...Open the advanced set up menu second menu item enter the number of complete cycles and pause time between these cycles for the connected solenoid valves With this mode unlike manual mode the device on...

Page 17: ...rating time Selecting The Number Of Outputs The number of outputs solenoid valves on which the economizer runs the cleaning cycle can be selected Cleaning is run in order from the first solenoid valve...

Page 18: ...device terminals 1 and 2 The outputs do not light up Output voltage Wiring to solenoid valves Check that the timer and solenoid vale output voltage agree Check wiring between timer and solenoid valve...

Page 19: ...ngs The default settings are S e t t i n g V a l u e Operating Mode Manual Pulse Time Valves 200 m sec Pause Time Valves Cycle 20 sec Number Of Connected Valves 1 Cleanings When Fan Is Off 2 Pulse Tim...

Page 20: ...L The manufacturer s address V i a P o 3 3 3 5 2 0 8 1 1 C e s a n o M a d e r n o I t a l y Declares that the product S e q u e n c e r Model E 7 T Complies with the following directives Directive 20...

Reviews: