Advanced Settings
Press the
Menu
key in the home page.
Use the arrows
to select Advanced Set Up.
Press
OK
key.
Use the arrows
to select the item to be set.
Use keys
to increase or decrease the value and change the item
conditions. Press
exit
to save and exit.
Set Op er ation
Sel ectabl e Parameter s
Cleaning Fan off
Number of complete cleans with fan off for
the number of connected solenoid valves.
Pulse Time
Valve opening time in cycles with fan off
50 mSeconds ÷ 10 Seconds
Cycle Time
Interval between valve opening in cycles
with fan off
1 Second ÷ 7200 Seconds
Cycles Manual Special
If Special operating mode was selected in
basic set up, enter the number of complete
cycles for the number of connected solenoid
valves to be completed
Pause Cycles Manual Special
If Special operating mode was selected in
basic set up, enter the pause between the
number of cycles