background image

■ 

In good ventilation.

• Place the refrigerator in

good ventilation for a good
operation.

■ 

Install the refrigerator at

indoor not to get wet from
the rain.

• This unit is designed for

indoor usage only.

■ 

Install the refrigerator on

the places with 41~95°F.

• The stored materials could

be frozen or broken below
41°F and cooling efficiency
could be lower over 95°F.

■ 

Place the refrigerator on

hard and level floor.

• Unlevel floor may cause the

refrigerator to make noise.

■ 

Avoid places that are

exposed to smoke.

• The discoloring can occur to

the refrigerator.

■ 

Set the front of the 

refrigerator a little bit
higher than back-side by
using adjustable feet to
drain the water away
easily.

■ 

Put away heat source from

the refrigerator.

• High ambient temperature

will make cooling efficiency
lower.

■ 

Place the refrigerator in an

area with low moisture.

• Splashing water or a high

moisture area may cause
short circuit and make
rusting easier.

■ 

Ajust the temperature in

the refrigerator.

• Controller is attached to the

right on the upper.

• Set the temperature control

at normal position.

2

Install
at the degree
of 41~95

°

F

Set the front
side higher than
back side.

HOW TO INSTALL

COOL

OFF

NORMAL

COLD

Summary of Contents for TGM-22R

Page 1: ... 정 3차 1998 11 6 11 9 8차 4차 9차 5차 10차 제 판 인 인쇄 쇄 규 격 MEMO 연 연락 락처 처 V VI IS SI IO ON N 담 담 당 당 전지현 TEL 757 9340 FAX 774 1039 3P 1page 재수정 99 8 20 한 2001 7 7 6P 1page 재수정출력 한 2001 12 12 Turbo Air로고 수정 한 2001 12 19 표지 2 4 5p 4page 수정 2001 12 26 5p 1page수정 2002 1 2 4p 1page수정 2002 1 8 4p 수정 2002 1 14 표지 3p 수정 2002 1 17 전체출력 2002 3 11 보증서수정 ...

Page 2: ...uctions completely BOTTOM GRILL ADJUSTABLE FOOT SHELF ADVERTISING PANEL DOOR ASS Y HANDLE HINGE U CONDENSER CONDENSER FAN CONDENSER MOTOR DRAIN PAN COMPRESSOR SUCTION PIPE COVER DRAIN HOSE DRAIN CAP EVAPORATOR COOLING FAN COOLING MOTOR BALLAST ADVERTISING PANEL FLUORES CENT LAMP HINGE T FEATURE CHART FRONT SIDE ...

Page 3: ...posed to smoke The discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable feet to drain the water away easily Put away heat source from the refrigerator High ambient temperature will make cooling efficiency lower Place the refrigerator in an area with low moisture Splashing water or a high moisture area may cause short cir...

Page 4: ...fore reoperating after a long period of non operation Condenser filter Take out the filter and clean it with brush or water 1 2 times a month Check points after cleaning Check again the refrigerator for safety Do not plug the power cord with wet hands Check the noise or overheating Caution Unplug the power cord before cleaning Clean the refrigerator periodically Do not use the abrasive cleaners so...

Page 5: ...nutes before re starting it Warning It is the responsibility of the purchaser in case of followings Compressor under low voltage Compressor more than 7 feet from plug in connection Compressor under unstable voltage Compressor not under 115V 60Hz Temperature control To keep the temperature down Turn the dial CW To keep the temperaure up Turn the dial CCW CAUTION Before you operate the unit Please u...

Page 6: ...frosting function You can feel warm by touching the refrigerator s front This is not a defect but a heater partly installed in the refrigerator BEFORE REQUESTING SERVICE Because of the differences between ambient temperature and a quantity of food stored when the temp dial is on the cold position Food would freeze in ambient temperature of below 41 F and the temp dial on the cold position When the...

Page 7: ... that Turbo Air determines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE ONE 1 YEAR WARRANTY AND THE ADDITIONAL FOUR 4 YEAR COMPRESSOR WARR...

Page 8: ...date of original installation but not to exceed five 5 years and three 3 months after shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The for 4 year extended compressor warranty applies only to hermeticall...

Reviews: