background image

8

Cooling operation

To select cooling operation mode, press the
mode button. Make sure the "

" indicator

appears in the remote display.

Set the temperature
lower than the room
temperature. The desire
temperature can be
changed up to 92°F and
down to 64°F.

Press the On/Off button on
the remote control to turn
the unit on; LED will light
on the indoor unit and the
unit will respond with beep
sound.

To select the fan speed, press the fan speed
setting button until the desired speed appears in
the remote dispay.(see below)

Summary of Contents for TAS-09SVH

Page 1: ...SPLIT AIRCONDITIONING SYSTEM OWNER S MANUAL TAS 09SVH 12SVH ...

Page 2: ...nits also When installing in a ceiling or wall make sure the ceiling wall is strong enough to hold the unit s weight A frame may be necessary for added support When installing in a room make sure the tubes are well insulat ed to protect the walls and furniture from sweating of the tubes When installing in moist or uneven locations make sure to use a raised level concrete pad or concrete blocks to ...

Page 3: ...ase refer to your contract with the power supplier If restrictions do apply for products like washing machines air conditioners or electrical ovens 4 For power details of the air conditioner refer to the rating plate of the product When Servicing Safety Instructions 2 Names of Parts 4 Indoor Unit 4 Outdoor Unit 4 Remote Controller 5 Operation 6 Prior to Operation 6 Auto Operation 7 Cooling Operati...

Page 4: ...ves The indoor and outdoor units are connected by copper tubes which are connected here Indoor Unit Outdoor Unit Flap Front Flap Bottom Air direction Timer Fan speed Room temperature TAS 09SVH 12SVH Connection Cover Remove cover to access the AC connection from this unit to the indoor unit ...

Page 5: ...isplay on unit Mode selection button Press to cycle through the modes Auto Cool Fan Dehumifier heat Timer On Off button Press to set the unit off or on time 0 5 1 1 5 2 2 5 3 4 5 6 8 10 12 16 20 24 Timer Enter Cancel timer button Press to enter a timer setting or to cancel timer setting Sleep button Press to set the unit for the sleep mode Temperature Reservation Time Indicatior Lights to indicate...

Page 6: ...S 09SVH 12SVH AC 250V 10A AWG 18 To install the batteries follow the procedures below HOW TO INSTALL BATTERIES 1 Open the cover after pressing the arrow direction and pulling out 2 Put the Alkaline batteries 1 5V AAA by direction 3 Close the cover after pushing into arrow direction BATTERY PRECAUTIONS The precautions below should be followed when using batteries in this device 1 Use only the size ...

Page 7: ...room temperature If you want to change the set temperature press the temperature setting button For temperature setting 72 F 80 F To select the fan speed press the fan speed setting button until the desired speed appears in the remote dispay see below Auto operation Press the On Off button on the remote control to turn the unit on LED will light on the indoor unit and the unit will respond with be...

Page 8: ... than the room temperature The desire temperature can be changed up to 92 F and down to 64 F Press the On Off button on the remote control to turn the unit on LED will light on the indoor unit and the unit will respond with beep sound To select the fan speed press the fan speed setting button until the desired speed appears in the remote dispay see below ...

Page 9: ...e mode button Make sure the indicator appears in the remote display To select the fan speed press the fan speed setting button until the desired speed appears in the remote dispay see below Press the On Off button on the remote control to turn the unit on LED will light on the indoor unit and the unit will respond with beep sound ...

Page 10: ...y Press the On Off button on the remote control to turn the unit on LED will light on the indoor unit and the unit will respond with beep sound Set the temperature lower than the room temperature The desire temperature can be changed up to 92 F and down to 64 F NOTICE If Dehumidification operation mode select you are not able to control fan speed ...

Page 11: ...temperature can be changed up to 92 F and down to 64 F Press the On Off button on the remote control to turn the unit on LED will light on the indoor unit and the unit will respond with beep sound NOTICE When the heating orperation is startded hot air delivery might be delayed due to warm up period To select heating operation mode press the mode button Make sure the indicator appears in the remote...

Page 12: ...get desired time Then if pressing Enter Cancel button On timer mode will be started If you want to stop On timer mode please press Enter Cancel again Press the Enter Cancel button to input the setting into memory the unit will beep the TIMER indicator will light on the unit and the TIMER indicator on the remote will light to indicate the unit is in the timer mode Repeatedly press the TIMER On Off ...

Page 13: ... and set the desired up down airflow direction Focus Wide button Used to stop and start louver movement and set the desired airflow direction downward concentrately Focus Wide button Used to stop and start louver movement and set the desired airflow direction far away concentrately Used to Focus Wide button to below the airflow direction far away below concentrately see below Press to select up do...

Page 14: ...e operation function NOTICE Time change is possible within 5 seconds at setting initial time after 5 seconds press the sleep button will cancel sleep mode Sleep operation Turbo operation NOTICE In case of TAS 09SVH 12SVH Turbo operation running time is limited with in 30 minutes after 30 minutes it will be return to previous operation mode 1 Press the Turbo button 2 When you want powerful cool hea...

Page 15: ...edures below 1 To the unit turn on press the ON OFF switch once 2 The unit will then turn on and depending on the room temperature it will select the or dehumidifier fan speed and fan direction automatically 3 To the unit turn off press the ON OFF switch once again ON OFF switch ON OFF switch ...

Page 16: ...filters use a vacuum and clean off dust Use water and mild soap also if necessary NOTES The filters should be changed every 6 months If in a climate with cold winters once a year is adequate 5 Insert cleaned or new filters back into the unit 2 Remove the Carbon Enzyme Filter 4 Insert cleaned or new small filters Carbon and Enzyme back into the unit Caution When you remove the electric dust collect...

Page 17: ...with the supplied cover this is very important to protect this unit BEFORE THE SEASON Make sure the air filters are clean Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions Make sure the unit is grounded Consult a serviceman for help PRECAUTIONS Do not use this unit for animal or plant storage In a lightning or thunder storm immediately unplug it from th...

Page 18: ...18 TROUBLESHOOTING GUIDE To change or clean the two air filters follow the procedures below ...

Page 19: ... incorrect or insufficient AC supply voltage Installation set up or adjustments of consumer controls Any owner than the original owner Damage from modification or incorporation into other products Any failure loss damage or person injury due to accident neglect or abuse by the consumer or to improper operation maintenance or storage or to alteration or to failure to follow normal procedures as out...

Page 20: ...20 ...

Page 21: ...p_실외기수정 07 7 11 4p_실외기내용수정 07 7 25 표지 4p_수정 07 8 06 4 5 7 8 10 11 12 13 14 수정 신규9p 07 8 07 5 7 8 10 11 12 13 14 수정 07 8 08 표지앞 뒤 수정 신규2p 07 8 20 2 5 7 8 9 10 11 14 수정 07 8 21 14 수정 07 8 21 3p 목차 부분 바탕에 깔린 DAEWOO 로고 삭제 07 9 04 표지 4 14 모델명삭제수정_ 신규3p 07 9 05 14 19 페이지삽입 수정_ 신규1p 연 연락 락처 처 V VI IS SI IO ON N 담 담 당 당 이지혜 TEL 02 730 0660 FAX 02 730 3788 V VI IS SI IO ON N C CR RE EA AT TI IV VE E I IN N...

Reviews: