25
Servicing
Thoroughly clean the pump and the drive assembly
in regular intervals, at least once a year. In case of
unfavourable conditions, such as high lime content,
a lot of sediment or failures, shorter intervals may
be necessary (about every three months).
Open the pump as shown in illustration (1) and pull
out the drive assembly (2).
Clean all parts, which includes the impeller housing,
the drive assembly with impeller as well as the rotor
compartment.
Never use hard objects to remove the dirt, but
rather a brush or soft cloth with detergent and/or
vinegar. If the drive assembly is too loose and has
too much clearance, replace the entire part (article
No. 6025.700 / 6055.700 / 6095.700).
The assembly is carried out in reverse sequence.
Entretien
Nettoyez régulièrement l’entraînement de la pompe,
au moins 1 x par an. Lors de conditions d’utilisation
sévères, par ex. eau très calcaire ou forte présence
de mucus, nous conseillons des nettoyages plus
fréquents (env. tous les 3 mois).
Ouvrez la pompe comme sur figure (1) et retirez
l’entraînement (2).
Nettoyez toutes les parties comme le corps de
pompe, l’entraînement avec hydropulseur ainsi que
la chambre du rotor.
N’enlevez jamais les incrustations calcaires à
l’aide d’un objet tranchant mais en vous aidant de
brosses, de pinceaux et de vinaigre blanc.
Si l’entraînement de pompe devait accuser un jeu
trop important sur son axe, renouvelez la pièce (réf.
6025.700 / 6055.700 / 6095.700).
Le remontage obéit à l’ordre inverse de démontage.