REAR PANEL
Chassis ground screw:
The chassis ground screw must be properly connected to the chassis of your vehicle before operating
the inverter.
Fan(s):
In order for the inverter to properly operate, the fan(s) opening must never be obstructed. Allow at
least six inches of clearance around the inverter for airflow. All fans are thermostatics and operate
upon the interior temperature of inverter.
REMOTE CONTROL
ON/OFF:
Your inverter is equipped with one 6 meters jack remote switch. The remote switch allows you to
mount your inverter out of sight and turn it ON or OFF from a convenient location. The ON/OFF
switch on the inverter’s front panel must be turned on for the remote to be operational.
Input Voltage:
By pressing the “SELECT” button until the “INPUT VOLTAGE ” light comes on, the battery voltage
indicator displays the voltage at the input terminal of the inverter. Usually this voltage is very close to
the battery voltage and the difference, if any, is caused by the resistance of the cables and
connections. A regular maintenance will contribute to minimize the possible resistance (see 5).
Output Power:
By pressing the “SELECT” button until the “OUTPUT POWER” ligh comes on, the watts indicator
displays the current provided by the inverter in KW. 1 KW = 1000 watts. If you read 1.20, it means
the inverter is providing 1200 watts.
“FAULT” light:
An audible alarm will sound announcing a faulty condition such as: low or high battery voltage and
overload.
“OVERTEMP” light:
An audible alarm will sound announcing an overtemp condition.
“LVP” on display:
Indicates the inverter is in Low input Voltage Protection mode (see 4.3).
“OLP” on display:
Indicates the inverter is in High input voltage Protection mode or if your consumption exceeds the
nominal capacity of the inverter (see 4.3).
3
Permanent Installation
The use of the Tundra International installation kits is strongly recommended.
These complete installation kits are custom
designed to maximize performance. It has been developed to promote safe installation and to help eliminate the difficult task of
sourcing the requisite and right material.
Recommended material
HD1224
HD & HDI1824
HD2524
HDI3024
-
Tundra CM series installation kit
CM1000 CM1200/1500
CM1800/2000 CM2500
Or
-
Welding cable AWG #4
AWG #2
AWG #1/0
AWG #2/0
-
Battery copper cable No. 8 AWG
-
PVC strain relief for flexible cable ½”
½”
¾”
¾”
-
6 Tin plated terminal lugs
-
CNL fuse block
-
CNL fuse 100A
150A
200A
250A
-
Plastic « loom » tubing
-
Heavy duty AC power distribution center
-
Red and black heat shrinkable tubing
-
Plastic cable ties
-
Clamps and bolts