Tunap MF 929 Service Information Download Page 1

T U N A P. C O M

Service

 

Information

 

SI 929_0120 

The specifications provided in this Service Information sheet are the results of careful analysis. Any application-related specifications shall be viewed as recommen-
dations based on past experiences. Due to the wide variety of applications and work methods, we are unable to provide binding specifications. Therefore, there exists 
no contractual legal relationship, nor will secondary obligations arise from any purchase contracts. Only the most recent version of the Service Information sheet 
retains its validity. 
TUNAP GmbH & Co. KG | D-82515 Wolfratshausen | Tel. 08171 / 16 00 – 0 | [email protected] | www.tunap.com 

Cleaning of the Secondary air system 

with 929 Secondary air system cleaner & 14800V1 Tool Secondary-Air Cleaning 

 

Introduction 

Congratulations on your purchase of the TUNAP Tool Secondary-Air Cleaning and thank you for the trust you have placed in us. The 
TUNAP Tool Secondary-Air Cleaning allows you to combine cutting edge technology with high customer satisfaction and sustainable 
cost reductions. To ensure full functionality of the system, please carefully read and observe the information compiled in this Service 
Information/Manufacturer Instructions. 
  

Special safety instructions 

Please read carefully this service information / manufacturer instructions completely before you use for the first time the TUNAP Tool 
Secondary-Air Cleaning. 
 
The TUNAP Tool Secondary-Air Cleaning should be used exclusively from professionals in the automotive area and it is approved only 
for the following process: 

 

Cleaning of the secondary air system in Gasoline vehicles. 
  

All safety precautions must be observed in order to avoid damage to the equipment, the secondary air system that is being cleaned, and 
avoid injuries. 
 

Safety instruction regarding the chemistry 

 

Observe the current safety data sheet. 

 

Use of protective glasses, gloves, and appropriate protective clothing is mandatory when using the 
cleaning system. 

 

Synthetic materials and paint must be protected from contact with the cleaning fluid. 

 

The TUNAP Tool Secondary-Air Cleaning is approved to use with the 929 Secondary air system cleaner and the 930 Neutralisation 
solution secondary air. Use of non-approved cleaning chemicals can cause operational or safety problems. 
 

Safety indication regarding the tool 

 

Maintenance and service may be performed only by the manufacturer of the cleaning system. 

 

In order to assure safety, use only original TUNAP spare parts and accessories. 

 

If the connection hoses or connections get damaged, replace them immediately. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MF 929

Page 1: ...on Manufacturer Instructions Special safety instructions Please read carefully this service information manufacturer instructions completely before you use for the first time the TUNAP Tool Secondary Air Cleaning The TUNAP Tool Secondary Air Cleaning should be used exclusively from professionals in the automotive area and it is approved only for the following process Cleaning of the secondary air ...

Page 2: ...ning including the connection house with easy connector to the secondary air system 2 Service Information user manual for the TUNAP Tool Secondary Air Cleaning 1 Holder for cleaner and rinsing 7 Compressed air connection 2 Connection for spray can 8 Stopcock compressed air 3 Seal for connection spray can 9 Stopcock cleaner rinsing solution 4 Opener or pressurizer for cans 10 Connection house for s...

Page 3: ...he manufacturer when working on the secondary air system Use adequate protection like gloves glasses shoes etc Before you begin with the cleaning process please perform an diagnosis and store the data for comparison after the cleaning pro cedure Attention Should the conducts of the secondary air system be completely clogged diagnosis please don t apply this system as it won t work we need a flow r...

Page 4: ...completely Insert the can 929 Secondary air cleaner into the housing and make sure the head goes over the seal O ring pic 2 2 Now screw carefully the opener or pressurizer for cans into the can Make sure that the spike of the safety opening gassing is exactly in the center of the can bottom pic 3 By screwing in further a hole is cut in the bottom of the can and the compressed air from the transpor...

Page 5: ...e for the secondary air system from the tool pic 8 5 To get the cleaning fluid directly to the secondary air conducts we have to activate the system valve How you have to procce will depend on the system you are working on Either you have a valve that is activated via vacuum so you need a vacuum pump to activate the valve pic 9 or you have an electronic valve so please use the scanner to open the ...

Page 6: ...One can will take in between for 15 to 20 min The can is completely empty when opening the stopcock of the cleaner completely and no liquid comes out Afterwards close the stopcock of the cleaner but let the air run for up to 30 seconds then close the pressure regulator com pletely pic 13 Stop the engine remove the empty can 929 Secondary air cleaner in the reverse procedure of the steps 1 and 2 of...

Reviews: