TUNAP GmbH & Co. KG | D-82515 Wolfratshausen | Tel. 08171 / 16 00 – 0 | [email protected] | www.tunap.com
Cleaning of the Secondary air system
with 929 Secondary air system cleaner & 14800V1 Tool Secondary-Air Cleaning
Introduction
Congratulations on your purchase of the TUNAP Tool Secondary-Air Cleaning and thank you for the trust you have placed in us. The
TUNAP Tool Secondary-Air Cleaning allows you to combine cutting edge technology with high customer satisfaction and sustainable
cost reductions. To ensure full functionality of the system, please carefully read and observe the information compiled in this Service
Information/Manufacturer Instructions.
Special safety instructions
Please read carefully this service information / manufacturer instructions completely before you use for the first time the TUNAP Tool
Secondary-Air Cleaning.
The TUNAP Tool Secondary-Air Cleaning should be used exclusively from professionals in the automotive area and it is approved only
for the following process:
Cleaning of the secondary air system in Gasoline vehicles.
All safety precautions must be observed in order to avoid damage to the equipment, the secondary air system that is being cleaned, and
avoid injuries.
Safety instruction regarding the chemistry
Observe the current safety data sheet.
Use of protective glasses, gloves, and appropriate protective clothing is mandatory when using the
cleaning system.
Synthetic materials and paint must be protected from contact with the cleaning fluid.
The TUNAP Tool Secondary-Air Cleaning is approved to use with the 929 Secondary air system cleaner and the 930 Neutralisation
solution secondary air. Use of non-approved cleaning chemicals can cause operational or safety problems.
Safety indication regarding the tool
Maintenance and service may be performed only by the manufacturer of the cleaning system.
In order to assure safety, use only original TUNAP spare parts and accessories.
If the connection hoses or connections get damaged, replace them immediately.