19
•
Vibrator START delay (delay from 0 to 5 seconds)
Adjust trimmer T2
•
External enabling input (from another card)
connector 3: clamps 3+4 (closed contact = enabled input)
Insert bridge when remote enabling is not used
•
External enabling (for another card)
connector 4: clamps 1+2+3 (1+2 normally open and 2+3 normally closed)
•
Solenoid valve24VDC
connector 5: clamps 1+2 (operation parallel to vibrator with anticipation of 1 second and
delayed switch-off of 2 seconds)
•
Workpiece flow interruption alarm
connector 4: clamps 6 and 7
for alarm control with clean contact (alarm contact normally open)
For 24V lamp control, use
connector 3: clamp 1
connector 4: clamp 7
and make a bridge between
connector 3: clamp 2 and
connector 4: clamp 6.
Alarm
RESET
is automatic as soon as workpiece flow resumes.
•
Delay to workpiece flow interruption alarm (alarm from 0 to 30 seconds)
Adjust trimmer T3
•
Vibrator block RESET
connector 4: clamp 10 + connector 2: clamp 1
Vibrator block inserted (bridge between clamps 8 and 9 of the connector 4) in the event
of an alarm
•
24VDC output (0.1 A max)
connector 3: clamps 1+2
•
CARD OPERATION LED
Green ON
= START vibrator
Yellow ON
= TOP vibrator
Red ON
= alarm start