N. MOTOR ASSEMBLY
1. Install the o-ring (62) onto the motor (63)
and install the motor using four capscrews
(30). Tighten the capscrews to the proper
torque specification (see page 28 of this
manual).
Make sure you install the
motor with the belly of it
down and the case drain
port up.
2. If removed, install cartridge valve (75).
3. Install the counter-balance valve (28) into
the counterbalance block (79).
4. Install the o-rings (26) into the manifold
block (78) and counterbalance block (79).
Install the manifold block (78) and counter-
balance block (79) using four capscrews
(25).
5. Install hoses (1, 4, 87, 88, and 105).
6. Remove the oil level plugs (94 & 31) from
the brake cover (18) and gearbox cover (3).
Fill the brake and gearbox through the oil fill
hole located on top of the gearbox with the
proper oil until the oil reaches the oil level
holes. Replace the oil level plugs.