7
PARAMETER SETTINGS
● Press HOLD and UNIT together to enter the
parameter settings
● Use the following diagram to navigate through
the parameter settings:
Function
Display
Parameter Settings
Automatic
Power Off
OFF 10
0 = turn off auto power off
10 = power off automatically if no change within 10 minutes
30 = power off automatically if no change within 30 minutes
60 = power off automatically if no change within 60 minutes
90 = power off automatically if no change within 90 minutes
Power Saving Mode
BL 1
0 = turn off the backlight
1 = backlight only when the weight changes or keyboard is pressed
2 = constant backlight
Unit Conversion
UnS 1
0 = turn off unit switch function
1 = kg/lb
2 = lb/oz
3 = kg/lb/oz
Hold Function
Hold 1
0 = turn off hold function
1 = Peak hold - Grabs the highest weight
2 = Manual hold - Grabs the current weight
3 = Auto hold - Automatically holds data when stable
Hold Time
Ht 1
0 = turn off hold time
1 = 15 second hold time
2 = 30 second hold time
3 = 45 second hold time
4 = 60 second hold time
5 = 90 second hold time
Zero Range
(% scale is allowed
to zero, anything
after will be tared)
2Ero 1
0 = turn off manually zero setting
1 = Initial zero range ±10% max capacity,
Manual zero range ±2%
2 = Initial zero range ±100% max capacity,
Manual zero range ±100%
Negative Range
(% it can go nega-
tive before an error)
nEgr 1
0 = -20d negative display
1 = 10% MAX negative display
2 = 100% MAX negative display
Communication
Setting
trn 1
Set the serial interface data output method:
0 = Turn off serial interface data output
1 = Continuous sending mode, connect computer
2 = Print mode, connect printer
3 = Command request mode, connect computer
Baud Rate
bAud 1
1 = 9600bit/s
2 = 4800bit/s
3 = 2400bit/s
4 = 1200bit/s
5 = 600bit/s
KEY
Function
ON/OFF Exit
HOLD
Confirm
ZERO
Move Left
UNITS
Move Down