background image

 

 

RZ2 BioAmp Processor Operator’s Manual

 

 

 

 

 

 

Maintaining the RZ2 

Safety Notices 

This device has passed rigorous testing by Underwriters Laboratories and is UL compliant for 
CAT II installation in laboratories and other indoor environments. Before applying power to the 
RZ2 chassis, verify that the correct safety precautions are taken. 

 

WARNINGS!

  Read the following warnings prior to operation. 

 

If the device is damaged, or fails to operate according to the specifications described in 
this manual, disconnect the power cord and contact TDT support immediately. 

 

The mains disconnect for the device is the power cord.  To completely disconnect power 
to the device, the power cord must be disconnected. 

 

The power cord is to be readily accessible after installation and during operation. 

 

Before applying power to the device, you must correctly connect the power cord to a 
properly rated standard socket outlet provided with a protective earth contact. 

 

In the event of impaired ground protection, avoid using the device to prevent possible 
damage. 

 

When removing the power cord from either the power supply or socket outlet, grasp the 
plug, not the cord, in order to avoid damaging the cable. 

 

Do not attempt to disassemble the power supply or chassis by removing any of the 
exterior housing of the RZ2. If you experience any issues, contact TDT support 
immediately. 

 

Do not attempt to alter this device in any way that deviates from its intended operation as 
described in this operator’s manual. 

 

Capacitors contained inside the device may retain their charge even after power has been 
disconnected from its supply source. 

 

Operation of this device in the presence of flammable gases or fumes is strictly prohibited 
to avoid definite safety hazards. 

 

Do not subject this device to excessive vibration or shocks during handling or shipping, 
and avoid dropping the device. 

 

Although there is a protective screen over the ventilation fan, do not attempt to stick any 
objects into the fan. This may result in injury or damage to the device.  

 

Do not attempt to store this device where it may be exposed to prolonged periods of 
excessive sunlight, high temperatures, high humidity, or condensation. If exposed to such 
conditions, the device may no longer work properly and its specifications may no longer 
be satisfied. 

 

The device is for indoor use only and is not waterproof; do not get the device wet. 

 

Do not attempt to use this device in a manner unspecified by TDT. 

Summary of Contents for RZ2

Page 1: ...RZ2 BioAmp Processor Operator s Manual ...

Page 2: ...s is and is subject to being changed without notice TDT shall not be liable for errors or damages in connection with the furnishing use or performance of this document or of any information contained herein The latest versions of TDT documents are always online at www tdt com support htm A CAUTION informs users when failure to take or avoid a specified action could result in damage to the product ...

Page 3: ...building on the strengths of its predecessors while improving flexibility and overall processing power Functional Diagram The RZ2 device chassis houses an integrated zBUS communication interface and power source Power Supply The RZ2 s power supply is integrated into the device and is shipped from the factory with the desired voltage setting 115 V or 230V preset If you need to change the voltage se...

Page 4: ...3 Turn the power switch on and check that the power switch s blue LED is illuminated Disconnecting Power from the RZ2 CAUTION When removing the power cord from either the power supply or socket outlet grasp the plug not the cord in order to avoid damaging the cable To disconnect the RZ2 1 Turn off the power switch 2 Disconnect the power cord from the power supply 3 Disconnect the power cord from t...

Page 5: ...ted on the front panel of the RZ2 chassis contain sensitive electronics Refer to the RZ2 Technical Specifications in the System 3 Manual before making any connections The RZ2 is equipped with several different analog and digital I O capabilities The high speed and legacy fiber optic ports allow a direct connection to Z Series or Medusa Preamplifiers The RZ2 also includes onboard D A and A D conver...

Page 6: ... connecting the RZ2 to any PZ Preamplifier ensure that the wires are inserted correctly The RED label on the back of the RZ2 denotes the input for the red colored fiber optic wire Similarly another label titled RED is shown on the back of the PZ Preamplifier ...

Page 7: ... the plug not the cord in order to avoid damaging the cable Do not attempt to disassemble the power supply or chassis by removing any of the exterior housing of the RZ2 If you experience any issues contact TDT support immediately Do not attempt to alter this device in any way that deviates from its intended operation as described in this operator s manual Capacitors contained inside the device may...

Page 8: ...ate pops free gently slide the fuse plate and housing out of the power supply 4 The housing contains two fuses Replace the defective broken fuse s with a new 5 x 20mm 250V 1 6A rated slow blow fuse by gently pushing the end of the fuse into the fuse housing 5 Push the fuse housing back into the power supply and press gently until the clip clicks into place Cleaning the RZ2 Processor Device To clea...

Page 9: ... 3U Width Standard 19 rack mount Power Supply Integrated Maximum Working Voltage HI to earth ground 230V max LO to earth ground 230V max Main Voltage Rating 115 230 V 50 60 Hz 40 VA AC Installation Category CAT II Environmental Operating Temperature 0 to 40 C Storage Temperature 5 to 40 C Humidity 80 for temperatures up to 31 C decreasing linearly to 50 RH at 40 C Maximum Altitude 2 000 m Pollutio...