RZ2 BioAmp Processor Operator’s Manual  

Copyright 

© 2008-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. 

No part of this manual may be reproduced or transmitted in any form or by any means, 
electronic or mechanical, including photocopying and recording, for any purpose without 
the express written permission of TDT. 

Tucker-Davis Technologies 
11930 Research Circle 
Alachua, FL 32615 
USA 

Phone: 386.462.9622 
Fax: 386.462.5365 

Notices 

The information contained in this document is provided “as is,” and is subject to being 
changed, without notice. TDT shall not be liable for errors or damages in connection with 
the furnishing, use, or performance of this document or of any information contained 
herein.  

The latest versions of TDT documents are always online at 

www.tdt.com/support.htm

 

CAUTION

 informs users when failure to take or avoid a specified action could result 

in damage to the product or loss of data. 

WARNING

 calls attention to an operating procedure or practice that, if not correctly 

performed or adhered to, could result in personal injury or death. Do not proceed beyond 
a WARNING notice until the indicated conditions are fully understood and met. 

 

Updated: 1/17/2019 11:37 AM 

 

 

 

 

 

Summary of Contents for RZ2

Page 1: ...RZ2 BioAmp Processor Operator s Manual ...

Page 2: ...s is and is subject to being changed without notice TDT shall not be liable for errors or damages in connection with the furnishing use or performance of this document or of any information contained herein The latest versions of TDT documents are always online at www tdt com support htm A CAUTION informs users when failure to take or avoid a specified action could result in damage to the product ...

Page 3: ...building on the strengths of its predecessors while improving flexibility and overall processing power Functional Diagram The RZ2 device chassis houses an integrated zBUS communication interface and power source Power Supply The RZ2 s power supply is integrated into the device and is shipped from the factory with the desired voltage setting 115 V or 230V preset If you need to change the voltage se...

Page 4: ...3 Turn the power switch on and check that the power switch s blue LED is illuminated Disconnecting Power from the RZ2 CAUTION When removing the power cord from either the power supply or socket outlet grasp the plug not the cord in order to avoid damaging the cable To disconnect the RZ2 1 Turn off the power switch 2 Disconnect the power cord from the power supply 3 Disconnect the power cord from t...

Page 5: ...ted on the front panel of the RZ2 chassis contain sensitive electronics Refer to the RZ2 Technical Specifications in the System 3 Manual before making any connections The RZ2 is equipped with several different analog and digital I O capabilities The high speed and legacy fiber optic ports allow a direct connection to Z Series or Medusa Preamplifiers The RZ2 also includes onboard D A and A D conver...

Page 6: ... connecting the RZ2 to any PZ Preamplifier ensure that the wires are inserted correctly The RED label on the back of the RZ2 denotes the input for the red colored fiber optic wire Similarly another label titled RED is shown on the back of the PZ Preamplifier ...

Page 7: ... the plug not the cord in order to avoid damaging the cable Do not attempt to disassemble the power supply or chassis by removing any of the exterior housing of the RZ2 If you experience any issues contact TDT support immediately Do not attempt to alter this device in any way that deviates from its intended operation as described in this operator s manual Capacitors contained inside the device may...

Page 8: ...ate pops free gently slide the fuse plate and housing out of the power supply 4 The housing contains two fuses Replace the defective broken fuse s with a new 5 x 20mm 250V 1 6A rated slow blow fuse by gently pushing the end of the fuse into the fuse housing 5 Push the fuse housing back into the power supply and press gently until the clip clicks into place Cleaning the RZ2 Processor Device To clea...

Page 9: ... 3U Width Standard 19 rack mount Power Supply Integrated Maximum Working Voltage HI to earth ground 230V max LO to earth ground 230V max Main Voltage Rating 115 230 V 50 60 Hz 40 VA AC Installation Category CAT II Environmental Operating Temperature 0 to 40 C Storage Temperature 5 to 40 C Humidity 80 for temperatures up to 31 C decreasing linearly to 50 RH at 40 C Maximum Altitude 2 000 m Pollutio...