ADJUSTMENT PROCEDURE:

 

 

CAUTION: 

 

Before making any adjustment let the unit heat-up at least 15 min. 
Observe that the offset-voltage measured at the side chain jack socket, when the 
THRESHOLD is off, is not greater than +/- 15 mV DC in both position "fixed" and "manual".  
(tip is bus 1 and ring is bus 2).

 

 
If the voltage exceeds this value, replace either IC1 or IC2. 
 

For serial no. up to 15891 

THE GRE SHALL BE MARKED BETWEEN 1.225-1.285

  

 
For serial no. 15892 and onwards

 

THE GRE SHALL BE MARKED BETWEEN W1.20- W1.50

  

 

 
 
ADJUSTMENT OF BASIC GAIN:

 

 
1) 

Apply a signal of 1 kHz, -30,0 dBU into the input of the compressor. 

 

2) 

Turn the 

GAIN-

control fully clockwise. 

 
3) 

Set the 

RATIO-

control at 2:1 

 

4) 

Adjust the pre-set 

GAIN

 (located on amp/psu PCB) to an output-reading of 0,0 dBU. 

 

 
ADJUSTMENT OF COMPRESSION TRACKING

 

1) 

Turn the 

THRESHOLD

-control fully counter-clockwise. 

 

2) 

Set the 

RATIO-

control at 2:1. 

 
3) 

Set the 

BUS-select

-switch at 1. 

 
4) 

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor. 

 

5) 

Adjust the 

GAIN

-control to an output-reading of 0,0 dBU.  

 
6) 

Apply a DC-voltage of +250,0 mV into the side chain jack socket (tip) and observe that the 

output level has dropped to -10,0 dB. 

 
7) 

If this is not the case, adjust the level with P 2 (P 1)*, to obtain a drop of exactly -10,0 dB. 

 
 

The trimpots in parenthesis refers to PCB 870316-0,1,2 

 

 

 

(180515) 

Summary of Contents for CL 1B

Page 1: ...of both tubes valves are fed with a stabilized DC voltage The whole amplifier including input and output transformer and the power supplies are placed on one PC board Both input and output are balance...

Page 2: ...he unit which performs the most compression is controlling the others To choose which one you want to control select the attack release time the threshold and the ratio on that unit and turn the thres...

Page 3: ...o 40 dBU METER The VU meter switch has three positions 1 Input The meter is reading the level at the input socket 2 Compression The VU meter is reading gain reduction Its rest position is 0 VU and the...

Page 4: ...ected release time takes over is dependent upon the setting of the attack control The more CW the attack control is turned the longer time before the selected release control takes over The more CCW t...

Page 5: ...how much compression in dB we feel is needed for the various examples OVERALL COMPRESSION FINAL MIX COMPRESSION NEEDED 3 4 dB Attack release select Fix man Attack 2 o clock Release 10 o clock Ratio 9...

Page 6: ...ply a signal of 1 kHz 30 0 dBU into the input of the compressor 2 Turn the GAIN control fully clockwise 3 Set the RATIO control at 2 1 4 Adjust the pre set GAIN located on amp psu PCB to an output rea...

Page 7: ...above 8 Adjust P 3 until the meter is reading 10 0 VU 9 Remove the DC voltage from the side chain jack socket 10 Repeat step 6 9 NB The VU meter accuracy should be within 0 5 dB when reading compress...

Page 8: ...LYDKRAFT ApS Mose All 20 DK 2610 R dovre Denmark 8 Over view of the sidechain PCB PCB 870316 0 1 2 P2 P3 P1 P5 0VU 10VU 10dB Rel 10 Sec PCB 870316 3 P4 P3 P2 P1 0VU 10VU 10dB Rel 10 Sec 101115...

Reviews: