TTL Luftschleieranlagen - Controller UBT2-E

3. Technical  data

3.1 Technical data of controller UBT2-E

Electrical connection

data line, factory ready-made with plugs in several lengths,

8-wire, RJ45 (ISDN) plugs, lengths 6, 10, 20, 30, 50 m

Bus system

bus two-core, voltage supply two-core, 
2 cores doubled

Interface / bus system

bus, 8-wire with RJ45 8/8 -plugs (2x)

Connections

2x clambs, 3-core, max. 1,0 mm² (room sensor, outside sensor)

Keybord

1 central multifunctional wheel, 2 buttons for ON/OFF and
MODE selection

Display

LCD display, chromatic

Protection

IP 40

Operation temperature

0°C to +45 °C

Storage temperature

-10°C to +60 °C

Installation type

wall mounting, cable insertion from the rear side
(mounting over a blind junction box)

Cover

plastic, gray - front panel/operating surface silver colored

Dimensions (l x h x d)

122,0 x 70,0 x 35,0 mm

Weight

136 g

Conformity
(controller and internal 

connection board)

In accordance to 

Low Voltage Directive

 

2006/95/EG

 

EMC (Electromagnetic compatibility) -com

patible to 

EMC Directives

 2014/30/EU

In accordance to directives
DIN EN 60335-1 (Safety of electrical units) 

DIN EN 60204-1 (Electr. equipment of machinery)

3.2 Technical data for internal connecting board (ASP/PCB)

Connection (power supply).

Fans-connecting box:  230 V AC, 50 Hz, L, N, PE, 

 

 

 

clambs max 2,5 mm²

Heating connection:   400 V AC, 50 Hz, L1, L2, L3, N, PE, 
 

 

 

clambs max. 4 mm²

Fuse

F 16 AT microfuse

Interface / bus system

bus, 8-wire with RJ45 8/8 -plugs (2x)

Connections, at control side

clambs (numbers see wiring diagram), max. 1,0 mm²

Output messages

operation message (NC), failure mess. (NC)

Inputs

3x (BMS release, external automatic contakt - door,
 room sensor)     --- to connect potential free

Summary of Contents for UBT2-E

Page 1: ...UBT2 E Controller for TTL air curtain systems with electric heating User manual Translated English version...

Page 2: ...contact control 9 7 3 Mode AutoTA automatic mode with anti cooling protection AKS 9 7 3 1 AutoTA automaticmode with AKS protection and door contact 9 7 4 Mode AutoRT automatic mode with room temperat...

Page 3: ...placing of covers or inappropriate maintenance Do never open the covers during operation Do always cut off the power supply before opening and switch off repair switch Assembly disassembly start up re...

Page 4: ...The top part is screwed with 4 screws with the basic plate The screws are accessible below the cover plugs at the case edges Illustration Fixing measures base plate illustration not true to scale Fixi...

Page 5: ...Cover plastic gray front panel operating surface silver colored Dimensions l x h x d 122 0 x 70 0 x 35 0 mm Weight 136 g Conformity controller and internal connection board In accordance to Low Voltag...

Page 6: ...utton select desired mode by central multifunctional wheel operating modes Manual Automatic modes AutoTK AutoTA AutoRT Automatic operating modes AutoTK AutoTA AutoRT Check or adjust of parameters Valu...

Page 7: ...onelly groups Sutchlike units of a group will be controlled equal and operates at the same operating stage or power level By comparison to similar step switches TTL UBT E offers enlarged functions con...

Page 8: ...ymbol Clock symbol timer OFF Clock symbol orange timer set in advance Press the MODE key again to activate the selected operational mode also see point 8 Default setting fan step 0 heating step 0 symb...

Page 9: ...again to activate the selected operational mode If the temperature drops below the preselected value the system will switch to fan step 1 and heating step 1 WKH 6 GLVSOD ZLOO DVK UHG If the system us...

Page 10: ...WXQJ XQG HL XQJVVWXIH NDQQ GLH HL XQJ GH QLHUW abgeschaltet werden Dies gestattet einen Betrieb der Luftschleieranlage ohne Heizung also beispielsweise zur T rabschirmung im Sommer gegen eindringende...

Page 11: ...ed data After the air curtain has been switched on the speed will switch to setting 1 during 3 seconds and next to set ting 5 for another 3 seconds automatically Next the system will operate based on...

Page 12: ...re different at most 20 m Room temperature sensor dimensions 70 x 70 x 27 mm 11 Messages OHDQ OWHU QG RI DGMXVWHG OWHU OLIH WLPH OHDQ OWHU XUJHQWO Filter can cleaned by a vac cleaner or can wipped cle...

Page 13: ...13 Troubleshooting Error Display Possible cause Solution System is not working Display OFF 1RW HQDEOHG 6HQVRU GHIHFW No main power supply Not turned ON BMS DDC release fault Temperature sensor fault c...

Page 14: ...ual Step Heating Timer Timer Set temperature AutoTK Step Heating Timer AutoTA Step Heating R Temp cooling protection temperature AutoRT Timer Timer Week switching clock Basic Start up Date time Langua...

Page 15: ...by us If the product is altered in a manner not approved by us this declaration shall lose its validity Product designation Electronic controller for air curtain devices Model designation UBT2 E Appl...

Page 16: ...er de Imprint User manual for controller TTL UBT 2E Translated English version 01 Manufacturer TTL Torluftschleier GmbH 1 Edition January 2019 1 500 printed at chloreene free paper By TTL Torluftschle...

Reviews: