TTi’s
TrailPro
™
HandBook
5
Call 1800 816 277
www.tti.com.au
5
Operating Instructions
To commence spraying, connect the spray lance to the hose by tightening the
hose cap to the lance grip. Do not cross thread or over tighten.
• When mounting to an ATV make sure the current size ball is used. Check that the
spray tank is still secure after the first 15 minutes of operation and re-tighten if
necessary.
• Partially fill the tank with clean water
• Connect the battery clips to a 12V DC power supply (red- positive terminal,
black to negative terminal) ensuring sufficient current capability (amps) to suit
the pump. The pump’s maximum amperage requirement is shown on its name
plate.
• In order to prime the system and enable the pump to reach full pressure, depress
the hand lance trigger to release trapped air. The pump will automatically switch
off when the hand lance trigger is released.
• Pump cycling may occur with insufficient nozzle delivery. This continual switching
on and off will reduce battery and motor life. Should this occur, adjust the setting
of the nozzle tip until the cycling stops.