TT8900 OPT
–
Installation and Service Manual
Page 27 of 41
4) CFG A
Configuration A string. This is a 12-digit numeric string that controls the
behaviour of certain aspects of the TT8900 OPT. Any change to this
string must be done in consultation with Transponder Technologies.
5) CFG B
Configuration B string. This is a 12-digit numeric string that controls the
behaviour of additional aspects of the TT8900 OPT. Any change to this
string must be done in consultation with Transponder Technologies.
6) FMWARE
Represents the version number of the installed firmware on the T20
SCM control module.
7) TIMEOUT
1) DCA/CAS TIMEOUT (enter number of seconds). Default = 120
2) NO-FLOW TIMEOUT (enter number of seconds). Default = 240
7) USB PASSCODE Used to configure a passcode that would protect against unauthorised
transfers of transactions and valid IDs using a USB thumb drive.
3.4.5
Pumps
MENU SELECTION DESCRIPTION
1) NUM
Enter number between 01 and 32 that is assigned to a physical fuelling
position. (A position could supply up to three fuel products. This number
will appear on the icon on the video monitor screen (1 to 32)
2) CHANL
Enter 0, 1 or 2. This number reflects the channel number that the pump
is using. The TT8900 OPT supports two channels (1 and 2). If the status
of a pump is set to 0, the pump is not configured for use and will not
appear on the video monitor.
3) TYPE
The type of pump being used.
1) PEC
2) PDS
3) WAYNE
4) GILBARCO
5) EMAIL
6) SANKI
7) WAYNE CL
8) OTI
9) BS (Blue Sky)
4) ID
Enter number between 00 and 99. This number is the actual (pump)
number used by the communication protocol. The ID may be different to
the pump number, as displayed on its icon (defined by NUM)
5) H1-Gxx
The Group number to which Hose 1 is assigned.
6) H2-Gxx
The Group number to which Hose 2 is assigned.
7) H3-Gxx
The Group number to which Hose 3 is assigned.
8) MORE
1) H4-Gxx
The Group number to which Hose 4 is assigned.
2) ISLAND xx
Generally, an island number is assigned to a pump only when an
Authorisation Station (AS) is used on the island where the pump is
located. The island number restricts authorisation (of the pump) to that
particular AS.
A value of 0 is used to indicate that the pump can be authorised by any
AS.