Tsurumi’s Operation, Service, and Repair Manual 

 

Operating Instructions 

  15

IDLE CONTROL S

W.

 PILOT

AT 120/240V
AT 120V ONLY

 AC  120V/240V

 VOLTAGE  SELECTOR

CIRCUIT  BREAKER

GFCI

SW.

ON

120V  ONLY

OFF

 AC  120V

ON

OFF

TOTAL

20A

TOTAL

20A

30A

120V/240V

CIRCUIT BREAKER

PRESS TO RESET

CIRCUIT BREAKER

PRESS TO RESET

CIRCUIT BREAKER

PRESS TO RESET

OFF

O N

START

 ENGINE SW.

STARTER RESET SW.

ON

PUSH

OFF

TESTTE

ST

RESETR

ESE

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3-3: Model TPG

4

44

4

-7000HDXE 

Starter reset 
switch 

Voltage selector 

Receptacle 120V  

Receptacle 120/240V  

Idle control switch 

Engine switch 

Pilot 
lamp 

Circuit breaker  

GFCI switch  

Circuit breaker 
30A  

Circuit breaker 
30A  

Ground terminal 

Circuit breaker 
20A  

Receptacle 120V  

Summary of Contents for TPG4-3000HDX

Page 1: ...ed in the exhaust gases will endanger human lives Keep the generator at least 1 meter 3 feet away from any structure or building during use When a generator is located close to a building or nearby eq...

Page 2: ...nts TPG4 Fig 1 3 AIR CLEANER MAINTENANCE CLEAN ELEMENT EVERY 50 HOURS EVERY 10 HOURS UNDER DUSTY CONDITIONS WASH IN HIGH FLASH POINT SOLVENT SQUEEZE DRY THEN DIP IN CLEAN ENGINE OIL AND SQUEEZE OUT EX...

Page 3: ...ion increases the speed of the generator up to operating speed level When there is no load the engine speed returns to idle 5 The FULL POWER switch allows the generator to provide full rated power for...

Page 4: ...REAKER PRESS TO RESET CIRCUIT BREAKER PRESS TO RESET CIRCUIT BREAKER PRESS TO RESET OFF O N START ENGINE S W STARTER RES ET SW ON PUSH OFF TEST TEST RESET RESET Figure 3 3 Model TPG4 4 4 4 7000HDXE St...

Page 5: ...m must be made by a qualified electrician 2 Improper connections can allow electrical current from the generator to backfeed into the utility lines which may electrocute utility company workers or oth...

Page 6: ...UEL TANK DO NOT REFUEL WHILE SMOKING OR NEAR OPEN FLAMES OR OTHER SUCH POTENTIAL FIRE HAZARDS OTHERWISE FIRE ACCIDENT MAY OCCUR AVOID REPEATED OR PROLONGED CONTACT WITH SKIN OR BREATHING OF VAPOR KEEP...

Page 7: ...ator WARNING IMPROPER CONNECTIONS CAN ALLOW ELECTRICAL CURRENT FROM THE GENERATOR TO BACKFEED INTO THE UTILITY LINES WHICH MAY ELECTROCUTE UTILITY COMPANY WORKERS OR OTHERS WHO CONTACT THE LINES DURIN...

Page 8: ...mage to the engine 2 ELECTRIC START Model TPG4 7000HDXE NOTE The engine on the Model TPG4 7000HDXE generator is primarily started using the electric starter but may be started using the recoil starter...

Page 9: ...op the engine in an emergency set the ENGINE SWITCH to the OFF position b For normal use turn the AC circuit breaker to the OFF position c Disconnect battery cables d Turn the engine switch to the OFF...

Page 10: ...THE PLUG INTO RECEPTACLE AND TURN CLOCKWISE WARNING BE SURE TO GROUND THE GENERATOR IF THE CONNECTED ELECTRICAL EQUIPMENT IS GROUNDED NOTE Whenever a circuit breaker trips off during operation the ge...

Page 11: ...120V Rated Output is Available Unavailable 120V 240V Half of Rated Output is Available Rated Output is Available WARNING TO TAKE OUT POWER FROM TWIST LOCK RECEPTACLE INSERT THE PLUG INTO RECEPTACLE AN...

Page 12: ...ure 3 8 Fuel Valve 3 13 Oil Alert 1 The oil alert detects the fall in oil level in the crankcase and automatically stops the engine when the oil level falls down below the predetermined level 13 When...

Page 13: ...ime is in contact with an electrical ground such as a plumbing fixture wet floor or earth The ground fault circuit interrupter will not protect against short circuits or overloads The circuit breaker...

Page 14: ...ILS TESTING DO NOT USE YOUR GENERATOR CONTACT YOUR TSURUMI DEALER Inspection 1 Unplug all tools and appliances from the generator 2 Start the engine 3 Turn the circuit breaker to the ON position The G...