-5-

CAUTION

  •  Do not use the pump for pumping liquids other than plain water, such as 

oil, salt water, or organic solvents.

 

•  Use with a power supply voltage variation within ± 10% of the rated voltage.

 

•  Use the pump at the water temperature of between 0 and 40°C.

   

•  Failure to observe these precautions could cause the pump to malfunction, 

which may lead to current leakage or electrical shock.

 

Critical Use Pressure

CAUTION

   Do not operate the pump in an area that is exposed to a water pressure that 

exceeds the values given below.

 Pre-Installation Check

Using a megger, measure the resistance between the tip of 

the cabtyre cable plug and the ground pole (using alligator 

clips) to verify the insulation resistance of the motor.

Note:

 

The insulation resistance reference value of 20 MΩ minimum is based on a new or repaired 

pump. For reference values of a pump that has already been put into operation, refer to "7. 

Maintenance and Inspection" in this manual.

Note:

 To use the pump for a special solution, contact the dealer where the pump was purchased, 

or the Tsurumi sales office in your area.

Insulation resistance reference value 

= 20M Ω minimum

 Precautions During Installation

WARNING

  When installing the pump, be mindful of the pump's center of gravity and 

weight. If the pump is not suspended properly, the pump may fall and break, 

which may lead to injury.

CAUTION

  When installing or moving the pump, do not suspend the pump by the 

cabtyre cable. Doing so will damage the cable, which may cause a current 

leakage, electrical shock, or fire.

Refer to the installation examples illustrated below and pay attention to the points 

described below to install the pump.

 Product Specifications

CAUTION

  Never use the product under conditions other than those that are specified in 

the product specifications.

 Main Component Specifications

              *

 

The power plug could vary by 

country or region.

4 INSTALLATION

Applicable Liquids Type and Temperature

Storm water and waste water, ; 0 ~ 40℃

Pump

Impeller

Semi-Vortex

Shaft Seal

Double mechanical seal

Bearing

Sealed ball bearing

Specifications

Dry type submersible induction motor: single-phase

150W, 2 poles

Insulation

Class E 

Protection System (built-in) Miniature protector

Liquid Paraffin VG 32

Oil

Connection

32mm screwed flange

Motor

Critical Use Pressure   0.2MPa (2kgf/cm

2

) - discharge pressure during use

Summary of Contents for OM

Page 1: ...t the manufacturer will not assume any liability After reading this Operation Manual keep it in a location that is easily accessible so that you can refer to it whenever you need information while operating this product OPERATION MANUAL OM CONTENTS 1 BE SURE TO READ FOR SAFTY 1 2 PART NAMES 4 3 PRIOR TO OPERATION 4 4 INSTALLATION 5 5 ELECTRICAL WIRING 7 6 OPERATION 8 7 MAINTENANCE AND INSPECTION 1...

Page 2: ...ore serious problem In either case the categories pertain to safety related items and as such must be observed carefully WARNING CAUTION NOTE Explanation of Symbols PRECAUTIONS TO THE PRODUCT SPECIFICATIONS Do not operate the product under any conditions other than those for which it is speci fied Failure to observe the precaution can lead to electrical leakage electrical shock fire or water leaka...

Page 3: ...shock short circuit or fire PRECAUTIONS DURING TEST OPERATION AND OPERATION CAUTION WARNING Never try to operate the pump if somebody is present in the pump sump If an electrical leakage occurs it can cause electrical shock When changing power connection is needed to correct the direction of rotation be sure to turn off the power supply earth leakage circuit breaker etc and perform the work after ...

Page 4: ...aler where it was purchased or Tsurumi representa tive Improper repairs can result in electrical leakage electrical shock fire or water leakage Test operation STOP OFF OFF PRECAUTION TO POWER OUTAGE In case of power outage turn off the power supply The product will resume operation when the power is restored which presents serious danger to people in the vicinity WARNING power outage OFF CAUTION D...

Page 5: ... Inspecting the Specifications Check the nameplate of the pump unit to verify that it is the product that you have ordered Pay particular attention to its voltage and frequency specifications Inspecting the Accessories Verify that the following accessories are included in the package Operation Manual 1 Note If you discover any damage or discrepancy please contact the dealer where this equipment was ...

Page 6: ...es office in your area Insulation resistance reference value 20M Ω minimum Precautions During Installation WARNING When installing the pump be mindful of the pump s center of gravity and weight If the pump is not suspended properly the pump may fall and break which may lead to injury CAUTION When installing or moving the pump do not suspend the pump by the cabtyre cable Doing so will damage the cab...

Page 7: ...ipe is in the water the water in the pipe could flow backward when the pump is stopped If the end of the pipe is located lower than the water level the water could flow out even after the pump is stopped 3 During transport or installation do not kink the cabtyre cable or use is in place of a rope 4 With the cabtyre cable lifted slightly secure it to the hook a hook must be prepared in advance by pla...

Page 8: ...ay suitable for the pump available on the market Failure to follow this warning can cause electrical shock or explosion when the product fails or an electrical leakage occurs Make sure that the power supply and wiring have adequate capacity Grounding WARNING Make sure to install the ground wire securely Failure to observe this precaution could damage the pump and cause current leakage which may le...

Page 9: ...oduct Note Verify the specs on the pump s nameplate 2 Check the wiring power supply voltage the capacity of the ground leakage circuit breaker and the insulation resistance of the motor Insulation resistance reference value 20MΩ minimum Note The insulation resistance reference value of 20 MΩ min is based on a new or repaired pump For reference values of a pump that has already been put into operat...

Page 10: ...dings which will affect the life of the motor For this reason minimize the frequency of starting and stopping the pump Operating Water Level CAUTION Do not operate the pump below the continuous running water level longer than 30 minutes as it could damage the pump causing current leakage and electrical shock Trial Operation WARNING Never start the pump while it is suspended as the pump may jerk an...

Page 11: ... Exterior Verify that there are no damaged areas and that the bolts and nuts have not loosened Note If the pump must be disassembled for repair due to damage or loose bolts or nuts contact the dealer where it was purchased or the Tsurumi sales office in your area 7 MAINTENANCE AND INSPECTION Interval Monthly Daily Inspection Item Yearly Once every 2 to 5 years To be within the rated current Measuri...

Page 12: ...ump be disassembled and repaired Changing Oil Remove the oil plug and drain the oil completely Pour a specified volume of oil into the oil inlet Note The drained oil must be disposed of by waste disposal contractors in compliance with the laws of the respective country in which the pump is being used The packing and the O ring for the oil plug must be replaced with a new part at each oil inspection...

Page 13: ...om pump casing and the nine screws at the bottom of the strainer by using a Philips screwdriver 2 Remove the bottom pump casing and the packing together and use your hands to remove the debris from the impeller 3 After removing the debris check that the impeller spins smoothly by turning it with your hand 4 If the impeller does not spin smoothly remove the cross recessed head truss screw with flat ...

Page 14: ...f the float case must be cleaned To prevent the pump from operating improperly clean the float case according to the following procedure 4 Wash the inside of the case with water Then use your fingers to lightly press the protrusion at the bottom of the float case as shown in arrow a and press it in the direction of arrow b 1 Lightly grasp the top of the float case and hold the protrusion at the bottom ...

Page 15: ...ting it from operating 1 Secure the pipe support 2 Replace the bearing 3 Adjust the valve to an appropriate opening 1 Pipe support is loose 2 Motor bearing is damaged 3 Valve is too restricted 1 Repair or replace the affected parts 2 Change the operation plan 3 Check the nameplate and replace the pump or the impeller 1 Impeller or the pump casing is excessively worn 2 There is an excessive amount ...

Reviews: