TSOL-MP3000/MP2250/MS3000
V1.4
- 13 -
Plug the AC connector into the microinverter and connect the AC cable to the AC distribution box.
Step 3. Connect the DC cable
DANGER
·When the photovoltaic array is exposed to light, it supplies a DC voltage to the inverter.
WARNING
·Ensure that all DC cables are correctly wired and that none of the wires are pinched or
damaged.
·The DC conductors of this photovoltaic system are ungrounded and may be energized.
·The maximum open circuit voltage of the PV module must not exceed the specified
maximum input DC voltage of the TSOL micro inverter.
CAUTION
·If the DC cable is too short for installation, use a DC Extension Cable to connect PV modules
to the microinverter.
Install the PV modules and connect the DC cable to the microinverter.
While using TSOL-MS3000 microinverter, each DC input of microinverter can connect two PV
modules in series.