- 35 -
Figure 6.20 Auto-test Std result
If the test is failed, it will also show the trip value and trip time. And the inverter will stop output power to the
power grid.
Figure 6.21 Auto-test Fail
6.4.1.7 Auto-test Std
Auto-test Std can be started here. Press “
” or “
” to choose each test item, then press “
ENT
” to start this
test. The test result could also be checked.
6.4.2 Advanced Setting
Advanced setting needs to enter the password first.
6.4.2.1 Working Mode Setting
Working mode can be set here, include Auto mode, Time-of-use mode, Timing mode, Peaking-shaving mode
and Passive mode. Press “
” or “
” to choose the working mode and press “
ENT
”.
Figure 6.22 Parameter setting of working mode
Auto Mode:
When the solar is sufficient, electricity generated by photovoltaic system will be supplied to load
first, the surplus energy will be stored in battery, then the excess electricity will be exported to the grid. When
the solar is insufficient, the battery will release electricity to supply load.
Time-of-use Mode:
Battery charging time, charging power and SOC can be set, and these setting can be set as
a weekly schedule. For example, user can set from 9:00 to 14:00 every Monday to charge battery with 1000W
power and with 70% SOC.