3-2-5.Setting and readout of preset counter
Type of command
SCPRdddd・・・・
To set preset value dddd・・・・・ in decimal to preset counter.
Unit is Kcts.
Maximum value is 4,294,967 Kcts.
SCPRFdddd・・・・
To set preset value dddd・・・・・ in decimal to preset counter.
Unit is cts.
Maximum value is 4,294,967,295 cts.
Inquiry command format
CPR?
To read out preset count value.
Reply
Reply data is 8 digit decimal value. (Kcts unit)
CPRF?
To read out preset count value.
Reply
00010000
Reply data is 8 digit decimal value. (cts unit)
(If reply data is over 8 digit, the digit is as the count digit.)
3-2-6.Setting and readout of preset timer
Type of command
STPRdddd・・・・
To set preset value dddd・・・・・ in decimal to timer. (ms unit)
Maximum timer set value is 1,099,511,627 ms.
STPRFdddd・・・・
To set preset value dddd・・・・・ in decimal to timer.(μs unit)
Maximum timer set value is 1,099,511,627,776 μs.
Inquiry command format
TPR?
To read out preset timer value.
Reply
00123456
Reply data is 8 digit decimal value. (ms unit)
TPRF?
To read out preset count value.
Reply
00123456
Reply data is 8 digit decimal value.(μs unit)
4294967000
(If reply data is over 8 digit, the digit is as the timer digit.)
Type of command
STRT
Enable counter start.
Type of command
STOP
Enable counter stop.
00654321
3-3-2.Counter stop
3-3.Commands of counter operation
3-3-1.Counter start
15/28