3.SETUP mode

You can setup Encorder Counter in SETUP mode.
*When SETUP mode, Encorder Counter stops counting.

1) Setting Preparation and Completion

Turn on the Power ON SW, and you can use Encorder Couneter in a few seconds.
Setting values(MULT-P, DIR, Z-LED, ENCTYPE, LANCTRL, LAN IP:1, LAN IP2, Port no) are 
kept by battery backup.

a)

Push SETUP SW (then SETUP SW is lighted.)
LCD indicator display Setting Item.

degit→

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

+

0

1

2

3

4

5

6

→ M

U

L

T

-

P

+

0

0

1

2

3

4

5

1

NORMAL mode

SETUP mode

You can change setting by using (+)/(-) button under the LCD indicator.
Appearance of Cursor depends on setting item. 
When Cursor appears, You can change the position by using (←)/(→) button. 
You can change setting item by using PRESET SW.
See the order of setting items below.

MULT-P → DIR → Z-LED → ENCTYPE → TERMINTR → 
LAN IP:1 → LAN IP:2 → Port no → MAC

Setting items from LAN IP:1 to MAC are common for each channel.
So they are displayed only in A cannel LCD indicator. (MAC is Read-Only.)

b)

Push SETUP SW again, then all LCD return to NORMAL mode.
Encorder Counter starts runnig in a new setting, except for "LAN IP:1", "LAN IP:2" and
"Port no". If you change those setting value, turn off POWER ON SW after the display
returns to NORMAL mode, and trun on POWER ON SW again.

See the explanation of each setting item below.

2) MULT-P 

You can select count rate from 1,2,4 times of encoder input pulse by using (+)/(-) button.

3) DIR

You can change the relation between the direction of rotation(CW/CCW) and
count up/down direction(U:up/D:down).

4) Z-LED

You can select ENABLE/DISABLE by using (+)/(-) button.

5) ENCTYPE

You can select encorder type(L.D:Line Driber or O.C:Open Collector) by using (+)/(-) button.

6) Terminator

You can select ENABLE/DISABLE by using (+)/(-) button.

7) LAN IP:1(upper 2byte of IP address)

You can chanse IP address by using (+)/(-) button and (←)/(→) button.
Setting value is decimal number only. Default value is "192.168."

8) LAN IP:2(lower 2byte of IP address)

You can change IP address by using (+)/(-) button and (←)/(→) button.
Setting value is decimal number only. Default value is ".1.55"

9) Port no

You can set Port Number by usint (+)/(-) button and (←)/(→) button.
Setting value is decimal number only. Default value is "07777".

10) MAC

You can see MAC address , but cannot change the address.

4

Summary of Contents for ER2C-04

Page 1: ...a city Ibaraki pref 300 0013 Japan Phone 81 29 382 3031 Fax 81 29 832 2662 URL http www tsujicon jp E mail info2 tsuji denshi co jp APPLICATION OF ELECTRONIC DEVICES TSUJI ELECTRONICS CO LTD 4CH 2CH E...

Page 2: ...Contents Specification 1 Panel Layout 1 SETUP mode 3 Communication Command 4 5 Firmware Version Up 4...

Page 3: ...ear counter by Z phase signal input Clear Each channel can set by LAN communication commands 7 Scaling Can use scaling function significant figures 15 Scaled value pulse count offset multiplier parame...

Page 4: ...e most significant 7 digit is displayed When the most significant 7 decimal digit include a decimal point the most significant 6 digit is displayed upper scaled value lower preset value can be changed...

Page 5: ...ting Line driver type is selected at the time of factory shipment 5V power supply for encoder panel receptacle SRCN2A16 10S JAE cable plug SRCN6A16 10P JAE Line Driver Circuit ex pin4 5 pin6 7 and pin...

Page 6: ...all LCD return to NORMAL mode Encorder Counter starts runnig in a new setting except for LAN IP 1 LAN IP 2 and Port no If you change those setting value turn off POWER ON SW after the display returns...

Page 7: ...osition counter preset must be in within 10digit If the value is over the range maximun or minimum value is set VER 1 00 12 09 03 ER4C 04 Firmware version read request in case of Ver 1 00 FROM FROM0 o...

Page 8: ...tiplier setting channel A D must be in the format range 0 000001 999 999999 MR M Scaling Parameter multiplier read request OW Scaling Parameter offset setting channel A D must be in within 10 digit ra...

Page 9: ...ck File Snd button Then version up software starts sending While Encorder Counter is receiving the file SETUP SW will blink slowly When Encorder Counter finishes receiving SETUP SW will blink fast and...

Page 10: ...W SETUP SW will blink and go out Turn off POWER ON SW again and set DSW1 s switch1 off Turn on POWER ON SW again Encorder Counter will run using firmware version 1 00 Then try update again by using ne...

Reviews: