background image

- 2 - 

 

 

● Use the product described in this instruction manual by observing safety-related 

laws and regulations such as Ordinance on Industrial Safety and Health. 

● Observe the following during the installation, removal, or maintenance/inspection of 

the product: 

(1) Turn off the power switch. 
(2) Do not go below any equipment which may fall and drop. 
(3) Secure moving parts of the equipment so that they will not move unexpectedly. 
(4) Wear appropriate clothing and protective gear for the work. 

● Before starting trial operation or regular inspection, be sure to confirm the 

operation so that the Shock Monitor properly works as a protection device. 

● The Shock Monitor main unit is subject to conditions when it is used for a megger 

test. Follow the instruction in the instruction manual. 

● Do not work while the line is live. Be sure to turn off the power before starting work. 

Otherwise, an electric shock may result.

Otherwise, an electric shock may result.

Otherwise, an electric shock may result.

Otherwise, an electric shock may result.    

● The wiring, energization/operation, and maintenance/inspection of the Shock 

Monitor must be done by an engineer with expert knowledge. 
Otherwise, an electric sho

Otherwise, an electric sho

Otherwise, an electric sho

Otherwise, an electric shock, injury, or fire may result.

ck, injury, or fire may result.

ck, injury, or fire may result.

ck, injury, or fire may result.    

● Be sure to ground Terminal E of the Shock Monitor. 

Otherwise

Otherwise

Otherwise

Otherwise,,,,    an accident may result.

an accident may result.

an accident may result.

an accident may result.    

● When using a 400 VAC motor power supply, ensure that the Shock Monitor unit and 

400 V resistor are connected properly. 
Otherwise, an e

Otherwise, an e

Otherwise, an e

Otherwise, an electric shock or fire may result.

lectric shock or fire may result.

lectric shock or fire may result.

lectric shock or fire may result.    

 

 

● Ensure that this instruction manual is delivered to the end users. 

Also, let the end users carefully read the manual before using the Shock Monitor to 
ensure correct use. 

● If you do not have the instruction manual, contact your TEM dealer or a TEM sales 

office and request a copy by specifying the product name, model number, etc. 

● Do not disassemble the product or make additional work for modification. 
● This product contains several consumable parts (electrolytic

several consumable parts (electrolytic

several consumable parts (electrolytic

several consumable parts (electrolytic    capacitor, relay, etc.)

capacitor, relay, etc.)

capacitor, relay, etc.)

capacitor, relay, etc.). 

Check functions and operation periodically according to the instruction manual. If 
any malfunction is found, contact your dealer for repair. 

● Do not use the Shock Monitor in an atmosphere where any corrosive gas exists. 

Sulfidizing gases (SO

2

, H

2

S), in particular, cause corrosion of copper and copper 

alloy used in the printed circuit boards and components, resulting in breakdowns. 

● Do not allow the entry of foreign matter such as lint, paper pieces, woodchips, dust, 

or metal chips into the Shock Monitor. 

● Clean off dirt periodically because it may cause overheating of the product or fire. 
● When discarding the product, dispose it as industrial waste. 

    

C

o

n

te

n

ts

 

U

s

a

g

e

 

/N

a

m

e

s

 

S

a

fe

ty

S

a

fe

ty

S

a

fe

ty

S

a

fe

ty

    

In

st

al

la

tio

n

 

/W

ir

in

T

er

m

in

a

ls

 

C

on

n

ec

tio

n

 

O

p

e

r

a

ti

o

n

 

M

ai

n

te

n

an

ce

/In

sp

ec

tio

n

 

Sp

ec

ifi

ca

tio

ns

 

D

im

en

si

on

W

a

r

r

a

n

ty

 

    

WARNING 

CAUTION 

Summary of Contents for TSM4000M1

Page 1: ...s who will actually use this product Keep this instruction manual safe from loss until this product is discarded This product is subject to change without prior notice Instruction Manual Shock Monitor...

Page 2: ...medium to light injury or property damage can occur Even if the instructions are followed a serious consequence may result depending on the situation Be sure to exercise due caution and follow all of...

Page 3: ...0 VAC motor power supply ensure that the Shock Monitor unit and 400 V resistor are connected properly Otherwise an e Otherwise an e Otherwise an e Otherwise an electric shock or fire may result lectri...

Page 4: ...which the reference value has been subtracted that is the relative value to the reference value If the relative value reaches or exceeds the preset OUT1 or OUT2 level for example a relative value of 5...

Page 5: ...is cable length is insufficient optional cables of 3 m 5 m 10 m 20 m and 30 m are available Contact TEM when necessary 5 Part Names 5 Part Names 5 Part Names 5 Part Names LCD display LED indicators Op...

Page 6: ...7 Wiring 7 Wiring 7 Wiring Complete wiring by using only the socket before attaching the Shock Monitor main unit to the socket Connect a commercial power supply of 90 to 250 VAC 50 60Hz or a DC power...

Page 7: ...through sensor Motor rated current A Sensor model No No of times to pass wire through sensor 0 1 0 71 TSM U010 6 0 36 TSM U010 12 0 2 1 4 TSM U010 3 0 70 TSM U010 6 0 4 2 3 TSM U010 2 1 2 TSM U010 3...

Page 8: ...5 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit and their...

Page 9: ...minals are used to externally switch preset overload detection levels according to the load condition of the equipment The level can be switched according to the load condition which varies depending...

Page 10: ...ety Installation Wiring Terminals Terminals Terminals Terminals Connection Operation Maintenance Inspection Specifications Dimensions Warranty 1 mA max 100 200 5 10 V 0 Load ratio Analog output OUT1 O...

Page 11: ...onnection Connection Operation Maintenance Inspection Specifications Dimensions Warranty This diagram shows the case where the electromagnetic coil capacity of the electromagnetic contactor for motor...

Page 12: ...or the input to X1 X2 X3 X4 and X5 5 Connect a commercial power supply to the operational power supply Do not connect the secondary side of the inverter Contents Usage Names Safety Installation Wiring...

Page 13: ...of the output relay Reset the self holding status of the output relay Return to parameter 1 Show the Test Program mode switching screen Change to the Monitor mode Change to the Monitor mode Change the...

Page 14: ...for relative and absolute values which can be switched with the MODE key For power monitoring the displayed load ratio is a value calculated on the assumption that the selected motor capacity is 100...

Page 15: ...Time Operating relay Auto Reset ON Resets automatically 1 second Press the RESET key Whichever is longer is applied PROGRAM MODE SET 1 Parameter Lock 1 Unlocked 1 Parameter Lock 2 Locked 2 Motor Volt...

Page 16: ...after it is started even in the Monitor mode Counting starts when the detected electric power reaches 5 or the current reaches 10 of the rated current Set the period as short as possible based on the...

Page 17: ...et one second after the relay output condition is cleared 8 Output Relay O1 2 Auto Reset 5 P r o c e s s 5 P r o c e s s 5 P r o c e s s 5 P r o c e s s 1 1 1 1 When 2 is selected SET Make the set dat...

Page 18: ...value of 12 OUT3 Level within the specified period the relay output is not activated Relay output mode setting 1 Self Hold Self holding The status of the relay output is retained The status is reset b...

Page 19: ...load monitoring is disabled within this specified time When this specified time elapses and the load ratio has reached or exceeded the setting level for the Shock Time period or longer the relay outpu...

Page 20: ...y stop using the absolute value monitoring when a foreign material gets stuck ON ON Shock Time for OUT1 OUT1 Setting level RUN indicator OUT1 indicator OUT1 output relay ON Start Time Offset Offset Of...

Page 21: ...ce with a correct sensor Does the V phase motor wire pass through the current sensor Other phase U phase or W phase Install the wiring properly Is the No of times to pass the wire through the sensor c...

Page 22: ...ill not be turned on accidentally 3 Observe the guidelines listed in the Labor Safety and Health Regulation 4 When conducting a megger test or dielectric withstanding voltage test remove the Shock Mon...

Page 23: ...nductive load 110 VDC 0 2A Inductive load 24 VDC 4 mA 100 000 times of operation Analog output signal 0 to 10 VDC Other Inhibit function When the frequency changes by 4 Hz s or more the electric power...

Page 24: ...1P TSM4 PR1 TSM4 PL1 Contents Usage Names Safety Installation Wiring Terminals Connection Operation Maintenance Inspection Specifications Dimensions Dimensions Dimensions Dimensions Warranty 37 46 4 4...

Page 25: ...damages 18 3 Paid warranty Even within the free warranty period if a failure or malfunction occurs in the TEM product due to any of the following causes the investigation repair shall be charged 1 The...

Page 26: ...MEMO MEMO MEMO MEMO...

Page 27: ...MEMO MEMO MEMO MEMO...

Page 28: ...Ltd http tsubaki sg U S Tsubaki Power Transmission LLC http www ustsubaki com Taiwan Tsubakimoto Co http tsubakimoto com tw Tsubaki of Canada Limited http tsubaki ca Tsubakimoto Chain Shanghai Co Ltd...