b.
Access Password:
If the tag is password protected, it is necessary to check the Use Access password
and enter the password into the access password field.
c.
Write Kill/Access Password:
These fields are used to write the kill or access passwords.
d.
Lock actions:
Lock actions are used to set the permissions for different parts of the memory
such as EPC Memory, TID Memory and User Memory, and also to set permissions
for kill and access passwords. The following permission types are available:
Read/Write, Permalock, Permaunlock, Unlock. After the desired permissions are
set in the Lock actions section, click the “
Apply”
button to apply the lock actions.
e.
Kill Tag:
After filling the Kill password field, this section enables the user to execute the Kill
tag command that will permanently disable the tag, making it impossible to read
again.