NOTE: Extra stress is placed on machine if proper sharpness and adjustment is not
maintained.
If valve "kicks out" on the shear
arm return stoke, the detent will
have to be slightly tightened.
Tighten outer nut 1/4 turn and
tighten lock nut. Continue to cut.
If valve still "kicks out" readjust
it another 1/4 turn.
Hydraulic pressure to the valve
is to read 2800 PSI on the gauge.
If pressure adjustment is needed,
remove the cap and either loosen
or tighten adjusting nut beneath
the cap.
1.
Maintain reservoir oil level 3”(7.62 cm) from top with any brand or type of automatic
transmission fluid. The machine comes with AMSTAR automatic transmission fluid.
2.
Avoid contact with eyes, skin and inhalation. Change the hydraulic filter every 6 months.
Use 10 Micron hydraulic filter. To reorder TSI’s Hydraulic filter element is part #10130E. Please
reference model and serial # of your machine when ordering parts.
3.
Change engine oil every six months.