- 46 -
7.4
Sensor
This option is used to calibrate the selected sensor. We recommend calibrate the sensor
before printing when changing the media.
Item
Description
Default
Auto
Calibration
This option is used to set the media sensor type and
calibrate the selected sensor automatically. Printer will feed
2 to 3 gap labels to calibrate the sensor sensitivity
automatically.
N/A
Manual setup
In case “Automatic” cannot apply to the media, please use
“Manual” function to set the paper length and gap/bline size
then scan the backing/mark to calibrate the sensor
sensitivity.
Note: The “Media Capacity” item is used to calibrate the
media capacity sensor %.
N/A
Threshold
Detect
This option is used to set sensor sensitivity in fixed or auto.
Auto
Maximum
Length
This option is used to set the maximum length for label
calibration.
254 mm
Advanced
This function can set the minimum paper length and
maximum gap/bline length for auto-calibrate the sensor
sensitivity.
0 mm
Menu
Sensor
Auto
Calibration
Gap
Black Mark
Continuous
Preprint
Manual Setup
Gap
Black Mark
Continuous
Media Capacity
Threshold
Detect
Auto
Fixed
Maximum
Length
Advanced