3.10.4 RF Synthesizer control
sys synth set <dev> <value>
DEBUG
Change configuration for the TX/RX synths.
Parameters:
<dev>
Device number 0-3. TX synths are 0-1, RX synths are 2-3.
<value>
A hexadecimal value constructed from new register value +
register number. If register value is 0x1b40 and register number
is 3, the resulting command value is 0x1b403.
sys synth get <dev> <reg>
DEBUG
Get register setting from a TX/RX synth.
Parameters:
<dev>
Device number 0-3. TX synths are 0-1, RX synths are 2-3.
<reg>
Register number 0-8.
sys synth default
DEBUG
Set default configuration to all synths.
sys synth range <dev> <synth type (rfx)> [extend] [decimal]
DEBUG
Display TX/RX synth frequency range.
Parameters:
<dev>
Device number 0-3. TX synths are 0-1, RX synths are 2-3.
<synth type
(rfx) >
Choose “rf1” or “rf2”.
[extend]
Display extended statistics.
[decimal]
Display the tuning margin in decimal instead of hexadecimal.
3.10.5 RX/TX Switch control
sys switch status <dev>
Displays Open load or errors detected by the switch.
Parameter:
<dev>
Device number 0-1.
sys switch get <dev> all
DEBUG
Displays all register values currently set in the switch.
Parameter:
<dev>