background image

 

8

 

 

 

Step.3.

 Adjust 2-PIN SW to the ON, ON position (System configuration Mode) then power on 

TRP-C51.

 

 

Step.4.

 Select the PC R-S232 COM Port for TRP-C51. 

 

 

Step.5 

Click the “Read Configuration” button

 

to read the TRP-C51 firmware configuration. 

Summary of Contents for TRP-C51

Page 1: ...to change without prior notice in order to improve reliability design and function and dosed not represent a commitment on the part of the manufacturer No part of this manual may be reproduced copied or transmitted in any form without the prior written permission of manufacturer Acknowledgment Products mentioned in this manual are mentioned for identification purpose only Products manes appearing ...

Page 2: ... directionally RS 485 signals communication Support all common baud rate from 1 2K to 256Kbps Comfortable TRP BT configuration software Windows version RS 232 422 and RS 485 signal auto switching Master Slave connection mode selectable LED indicators for Power Link TX RX Surge protection on RS 422 RS485 Power supply Screw terminal or external DC adapter Wide input range power supply DIN rail and p...

Page 3: ... external DC adaptor 5 5 2 1 12mm 500mA Power consumption 1 2 watt Operating temperature 0 to 60 Storage temperature 20 to 70 Humidity 10 90 Non condensing Dimension 151mm X 75mm X 26mm Weight 400g 2 Hardware Description 2 1 Panel Layout ...

Page 4: ...r and Slave connection is successful D Blinking if there is activity such as data transmitting or receiving When TRP C51 is in Slave mode the LINK LED definition is as below Turn on off in the cycle of 1000ms on 3000ms off no connection Turn on When Slave and Master Connection is successful Blinking when there is activity such as data transmitting or receiving TX LED RS 232 422 485 data transmitti...

Page 5: ...system changes will be effective after the system reboot 2 4 2 The 4 Pin DIP Switch for option No function 2 5 Micro Touch button TRP C51 micro touch button provides user with new link function when user want to drop existing connection and create a new connection with new device The Micro touch button can only work when TRP C51 is defined as Master When TRP C51 is in Slave mode the button is no f...

Page 6: ...ollowing 2 power sources 1 External DC adapter 2 Screw terminal DC input Do not use both power input simultaneously 3 3 RS 232 wiring connection 3 4 RS 485 wiring connection The RS 485 mode supports the Transmit and Receive channels using 2 wire half duplex operation Refer to the pin assignment for connection as below The RTS CTS must be none if using the RS 422 485 function please refer to chapte...

Page 7: ...it 1 RTS CTS Flow Control Disable 4 2 Configure TRP C51 Step1 Use a Null modem cable crossover female to female cable to make a connection between the TRP C51 DB 9 connector and PC DB 9 connector Step 2 Run the TRP BT Utility by window User may find the TRP BT utility in TRP C51 support CD or download from Trycom web www trycom com tw Please note that copy TRP BY utility from support CD to the des...

Page 8: ...t 2 PIN SW to the ON ON position System configuration Mode then power on TRP C51 Step 4 Select the PC R S232 COM Port for TRP C51 Step 5 Click the Read Configuration button to read the TRP C51 firmware configuration ...

Page 9: ...9 Step 6 Select the baud rate from 1200 bps 256 K bps Step 7 Select the data bit form 5 8 ...

Page 10: ...10 Step 8 Select the Parity Check Step 9 Select the Stop Bit Step 10 Select the RTS CTS Flow Control The RTS CTS must be none if using the RS 422 485 function ...

Page 11: ...evice or Slave device here If define TRP C51 as a Master and input a Slave BD address this Master of TRP C51 will search only for the matched BD address of Slave device 5 How to use TRP C51 TRP C51 support direct link mode and paired connection mode User can use the host PC or Notebook which with integrated bluetooth interface to wirelessly connect TRP C51 after the installation system will genera...

Page 12: ...tions we use ET BD121 as example 5 1 Direct link mode Step1 Power on TRP C51 and select TRP C51 as slave TRP C51 accepts 10 30V DC 500mA power supply When power is correctly supplied the PWR LED will start lighting the system is up and discoverable Use TRP BT utility to select TRP C51 as slave Step 2 Install Bluetooth ET BD121 USB dongle driver and utility User may find ET BD121 USB dongle driver ...

Page 13: ...ress Finish to end the process Step4 Bluetooth setting After ET BD121 driver installed back to the Windows screen and Click Start Program file Bluetooth Bluetooth setting The Bluetooth settings screen appears Step5 Click on New connection icon into the Add New Connection Wizard the USB dongle start to search all discoverable TRP C51 units Suppose just only 1 TRP C51 unit need to be installed we ca...

Page 14: ... installation mode Select Express Mode The COM port is assigned by system Custom Mode Allow user freely to assign the COM Port to TRP C51 Confirm with Next In the next description we select Custom mode for explanation ...

Page 15: ... function enable or disable Step8 Select the installed TRP C51 icon and click mouse right button to check or change options User may rename or delete the TRP C51A here Select Connect option you are requested a Bluetooth passkey Please Input TRP C51 password which must be same as the setting by TRP BT utility press OK TRP C51 will go into searching mode the LINK LED start to fast blinking ...

Page 16: ...cessfully connected user may see the next screen the LINK LED stop fast blinking and turn to lighting TRP C51 is available to data communication or control You also may find TRP C51 has already been added in system device manager ...

Page 17: ... changes In this mode the data line signal and data format can be auto detected and converted between each other The communicating range can up to 100M 4 3 How to set up TRP C51 paired connection mode Step 1 Use TRP BT utility to set one TRP C51 as master and another TRP C51 as slave Both TRP C51 devices name and password must be same Step 2 Put both TRP C51 in system connection and power on the b...

Page 18: ...nd the utilities in Trycom support CD or download from Trycom web www trycom com tw The testing utility includes RS 422 test utility test422 exe for DOS DEMO exe for Windows and RS 485 utility test485 exe for DOS TRPCOM for Windows 6 1 RS 232 Loop Back Test RS 232 loop back test wiring connection 6 2 RS 422 Loop Back Test RS 422 loop back test wiring connection ...

Page 19: ...counter See the Figure 6 your system will detect the COM3 Fig 6 Please note COM3 is an example of COM port number user may get a different COM port number after the installation The actual COM port number is assigned by Windows system Step3 Click the Setting to set the RS232 loop counter See the Figure 7 your system will detect COM3 ...

Page 20: ...tion User may also directly link TRP C51 to Trycom Remote IO modules the wiring connection is as below Step1 Install TRPCOM utility TRPCOM is a test utility which may help user to test TRP C51 with RS 485 device easily User may find the utility in the TRP C51 support disk Double click Setup exe the install Wizard will guide you to complete the installation ...

Page 21: ...21 Step2 Configure COM port and baud rate after configuration press OK to the next screen Step3 Send command 01M and press Send Step4 Data response received Test complete ...