TRX SIEMENS UP0 EXTENDER User Manual Download Page 3

Siemens Up0 line extender 

 

Page 3 of 3 

CONNECTIONS 

 

The first extender operates at PBX site and is being powered directly from Up0 line.  
The second extender operates at system telephone site. Together with the telephone  – it needs to be 

powered by an external power supply dedicated for system phones (i.e. Salcomp C39280-Z4-C510). 

The power is being supplied on the second pair in a wire. The extender adds it to the digital signal on 

the first pair in wire and puts it back to the telephone via the power supply. This allows to connect the TDM 
telephone with a single pair wire and it will work.  

CAUTION: A short on a pair of wire to the phone will cause the malfunction of the extender. 

START UP 

If all connections are correct, pair of extenders will try to connect to each other. This can take up to 

several seconds, especially in cases of long wire length in between them or/and in harsh industrial conditions. 

After  the  link  between  expanders  is  established,  they  work  in  a  transparent  manner  from  the  audio 

signal point of view. Audio signal is retransmitted bit-perfectly. There is an option to encrypt audio data. For 
the signalling data additional features were developed to protect it from corruption and to ensure its delivery 
to the other side of the link. 

Up0  extenders  maintain  the  sync  in  between  PBX  and  the  TDM  telephone.  All  the  clocks  are  locally 

synchronised with DPLL. 

In  operation,  all  LEDs  shall  glow  in  green  colour.  Short  and  spontaneous  blinking  of  theirs  means 

unusually big phase correction for internal DPLL circuits and shall not cause concerns about device operation. 

FIRMWARE UPGRADE 

Firmware upgrade procedure: 

- turn the extender off, 
- prepare uSD card with FAT32 filesystem in it, 
- put firmware file in the root folder of the card, make sure it is called 

upgrade.upg

- put the card into the extender and power it up, 

The device shall update its firmware automatically, and start standard operation after a few seconds. 

Upgrade 

file will be deleted if the upgrade process was successful.

 