TRX SIEMENS UP0 EXTENDER User Manual Download Page 2

Siemens Up0 line extender 

 

Page 2 of 3 

APPLICATION 

 

Siemens Up0 Extender shall be used whenever there is a need to use Siemens TDM phones on remote 

locations (distance measured in kilometres from the PBX). 

 

FEATURES 

 

Up0 Extender increases the range of Up0 digital lines up to several kilometres. Its operation has been 

verified on a single pair AWG22 cable /φ = 0,643mm/ of length approx.12km, in industrial environment, loop 
resistance approx. 1200Ω. 

Works with any Siemens TDM telephone (different OptiPoint  and OpenStage phones were tested). 
Two devices per single Up0 line are required. 
The device is powered either directly from Up0 line of from external power source (DC 20-60V). Power 

consumption is below 1W. 

 

APPEARANCE 

 

SD – micro SD card socket, for firmware upgrades, 
S1 – LED signalling synchronisation on link between a pair of extenders, 
S2 – LED signalling synchronisation on Up0 line, 
POWER – LED signalling if the device is powered, 
OPT – piano switches for device configuration, 
USB – optional, for firmware upgrades, 
Up0 – socket to connect Up0 line to, 
LINIA – socket to connect the other extender to. 
 

CONFIGURATION 

 

For  a  pair  of  extenders  to  work  correctly,  it  is  necessary  to  setup  one  of  them  in 

at  PBX

  operating 

mode  and  another  one  in 

at  telephone

  operating  mode.  Piano  switch  OPT1  (first  from  the  left)  makes  it 

possible. 

 - 

at telephone

 operating mode, 

 - 

at PABX

 operating mode. 

 

Extenders will not connect to each other and solution will not work if  both have the same operating 

mode set. 

Options OPT2 and OPT3 are for fine tuning to UP0 line. For standard operation these do not need to 

be activated. 

 

 

 