10
10. Technical Specification
230 V ~ 50 Hz, Class I construction. Enclosure to IP20. With 15m supply cord and 13A fused plug.
Model
Valet Upright Vac
Valet Upright Vac
Ref No
VUV-QD
VUV-QD/EURO
Tank material
ABS
ABS
Voltage a.c.
V
230
230
Frequency
Hz
50
50
No. of motors
1
1
Motor rating
W
1200
1200
Capacity – dry
L
3.6
3.6
Construction class
I
I
Protection
IP
IP20
IP20
Airflow
l/sec
52.5
52.5
kPa
16.2
16.2
Vacuum
mm/wg
1651
1651
Cable length
m
12
12
Size (l x w x h)
cm
35 x 37 x 114
35 x 37 x 114
Weight
kg
6.6
6.6
Noise Level (
see
note 1)
dB(A)
79
79
1 – Sound pressure level under normal operating conditions is 79dB(A) when measured at a distance of 1
metre from machine and 1.6 metres above the floor. Measurements recorded using hand held meter.
11. Fault diagnosis
WARNING - Before undertaking maintenance operations or adjustments switch off
machine and unplug from the electricity supply.
The following simple checks may be performed by the operator.
Trouble
Reason
Remedy
Machine not working.
Lack of voltage/electrical
supply.
Check fuse *, supply cord, plug
and socket outlet.
Loss of suction
Bag full.
Blocked hose or wand.
Motor not working
Replace bag
Remove obstruction
Contact supplier
Motor is not running
Broken switch
Defective power cord
Defective motor
Contact supplier
Contact supplier
Contact supplier
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.