When Cleaning is Finished

 

Draining and Cleaning

 

 When the recovery tank is full, empty by using the 

drain hose at the rear of machine (Fig 2). If a bucket 
is used to empty the recovery tank, do not use the 
same bucket to fill the solution tank as this can 
result in putting dirt and grit into the solution line that 
can block filters, orifices, and generally degrade the 
solution line system (do not reuse solution).  Take 
care if using a bucket to empty the machine.  Stop 
flow before bucket overflows.  Empty bucket and 
repeat. 

 

Fig 2 

 

 To empty solution tank, detach the wand from the 

end of the vacuum hose and insert the vacuum hose 
into the solution tank. Turn the vacuum switches to 
the "on" position and transfer solution to recovery 
tank and dispose of as outlined above. Clean 
recovery filter at this time. 

 

Transporting the machine 

Incorrect lifting techniques may result in personal 
injury. We advise that the manual handling regulations 
are followed.  Do not expose the machine to rain or 
moisture.   
 
When transporting the machine ensure that all 
components, tanks and removable parts are securely 
fastened, and that the supply cord and plug are not 
trailing.   
 
Do not list or transport the machine whilst containing 
liquid as this will add considerably to the weight. 
 
Take extreme care when moving the machine up or 
down steps or stairs. 
 

Storage 

 Always switch off, empty, wipe down and dry the 

machine after use. 

 Both the solution and recovery tanks should be 

emptied and flushed out with clean water to ensure 
the seals and pumps are free from any cleaning 
detergents.  

 We recommend running the vacuum motor for 

approx. 2 minutes after use to eliminate 
condensation within the machine body, thus 
ensuring the motor and particularly the bearings 
remain dry. 

 Store machine with recovery tank lid removed and 

dump valve open (Fig 3).  Deodoriser may be left in 
the tank to prevent unpleasant odours.

 

 

  

Fig 3 

 Wrap supply cord around handle ensuring that plug 

is not trailing on the floor.  Store the machine in a 
dry indoor area only. 

 Store the machine in a dry indoor area only. 

 

Maintenance 

WARNING 

Before undertaking 

maintenance operations or adjustments 
switch off machine and unplug from the 

electricity supply.

 

IMPORTANT

 – All other servicing 

and repairs should only be performed by a Truvox 
engineer or Authorised Service Agent. 

IMPORTANT

 – 

Should the machine fail to operate please refer to the 
fault diagnosis section in the back of this instruction 
manual. If the problem / remedy is not listed please 
contact Truvox Customer Service Department for 
rapid attention. 
The machine requires minimum maintenance apart 
from the following checks by the operator prior to use:  

 DO NOT use aggressive detergents, acid, lye etc. 

during cleaning and washing and take particular 
care with electrical parts. 

 

Supply cord

  -  Regularly inspect sheath, plug and 

cord anchorage for damage or loose connection. 
Only replace the supply cord with the type specified 
in these instructions. 

 

Solution tank 

–  Check filter is clean and 

undamaged. A damaged or missing filter must be 
replaced or damage to pump head and spray jet 
could occur. 

 

Vacuum head 

–  Check and remove any debris or 

lint build-up from the head. 

 

Spray jet 

–  Check jet for blockage and full spray 

pattern. Blow through jet to clean. 

Do

 

not 

use a pin, 

as this could damage the jet. 

 Lubricate brass quick disconnects and drain valves 

with a quality lubricant such as WD-40. 

 Flush solution systems after use with clear, clean 

water. (A white vinegar solution may also be used). 
This will counter-act hard water and alkaline 
deposits and aid in keeping orifices clean. 

 Do not allow fluid either in solution or waste tank to 

sit overnight. The unit should be emptied and 
cleaned daily. 

 Clean the filter in the solution tank, the filters on the 

vacuum stack in vacuum tank and all lint filters in 
the inlet or vacuum tanks daily. 

 Do not use the same bucket to fill solution tank that 

is used to remove waste from recovery tank. 

 When the unit is not in use, leave the recovery tank 

lid open. 

 At the end of each day, run the vacuum for 2 

minutes with lid open and filter off. 

 

After sales service

 

Truvox machines are high quality machines that have 
been tested for safety by authorised technicians. It is 

Summary of Contents for Hydromist 55/100

Page 1: ...ORIGINAL INSTRUCTIONS CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE Hydromist 55 HM55 100 HM55 400 USER MANUAL EN MANUEL D UTILISATION FR 03 8196 0000 Issue 7 04 15...

Page 2: ...8 D pression la colonne d eau In mm 150 3810 150 3810 Niveau sonore dB A 86 86 Dimensions L x W x H cm 87 x 61 x 115 87 x 61 x 115 Poids vide kg 47 60 5 Longueur de c ble m 15 15 Garantie 1 year Les d...

Page 3: ...ser en pr sence de poussi res pr sentant un danger 19 Ne pas utiliser dans des endroits pr sentant des risques d explosion 20 NE PAS aspirer ou utiliser proximit de liquides poussi res ou vapeurs infl...

Page 4: ...est en marche le voyant orange du panneau de contr le est allum Retirer le tuyau du r servoir connecter le tuyau d aspiration l appareil et raccorder aux autres extr mit s la canne outil de surface R...

Page 5: ...ilisation d un seau pour vidanger ne pas utiliser le m me seau pour remplir le r servoir de solution pour ne pas y injecter les salissures r cup r es lors de la vidange et boucher les filtres et les g...

Page 6: ...service Truvox machines are high quality machines that have been tested for safety by authorised technicians It is always apparent that after longer working periods electrical and mechanical component...

Page 7: ...5 litre 4 HMC01050 Hydromist Pre spotter 500ml 10 HM003005 Sa formulation convient l limination des taches persistances des moquettes et tissus IMPORTANT Les accessoires d origine et les produits chim...

Page 8: ...s 1 Contr ler la vanne et enlever les salissures et corps trangers 2 Faire ventouse la sortie d eau du r servoir de solution si la solution coule le syst me est correct Si non contr ler si les connec...

Page 9: ...0 150 3810 Sound pressure level dB A 86 86 Dimensions L x W x H cm 87 x 61 x 115 87 x 61 x 115 Weight kg 47 60 5 Cable length m 15 15 Warranty 1 year Above dimensions are approx Since the company s po...

Page 10: ...CAUTION If it is suspected that there is hazardous dust or flammable materials stop cleaning the area immediately and consult your superior 22 DO NOT use to clean up any burning or lighted materials...

Page 11: ...one product empty the recovery tank rinse out and continue checking regularly for foam build up When solution spray ceases the solution tank is empty Switch off the machine empty the recovery tank an...

Page 12: ...door area only Store the machine in a dry indoor area only Maintenance WARNING Before undertaking maintenance operations or adjustments switch off machine and unplug from the electricity supply IMPORT...

Page 13: ...This guarantee is governed by the laws of England 5 This guarantee does not cover any of the following Periodic maintenance and repair or replacement of parts due to normal wear and tear Damage caused...

Page 14: ...lve Recovery tank lid must be closed 2 Repair or replace hose Remove kinks in vacuum hose 3 Open machine connect vacuum hose to recovery tank Not enough vacuum power at the machine 1 Damaged recovery...

Page 15: ...screen 2 Remove and clean Leaking or stuck solution valve 1 Foreign material in valve 2 Loose brass hex nut 3 Valve worn or seals worn 1 Remove brass hex plug clean valve and replace 2 Reseal hex and...

Reviews: