If despite making the corrective actions recommended the problems continue,
contact a Authorized Service Center
9
Troubleshooting
• Double-check the cable and fuse.
• Prevent the cause of overheating. Wait for the
water to cool down.
• Remove obstructions from the ventilation
slots.
• Switch on the FI switch. If it fails again contact
a Authorized Service
Center.
• Contact a Authorized
Service Center.
• Double-check there is enough water supply.
• Seal the suction pipe, repair leaks and tighten
all the connections.
• Set the pump not higher than 26,2 ft above the
water container. See page 3.
• Clean or replace filter.
• Clean or replace valve.
• Go to a Authorized
Service Center.
• Clean the pump with clear water and remove
any obstructions there are.
• Fill the pump receptacle with water
For suction pipes with check valve, fill the
suction pipe with water.
• Double-check the container and the water
quality.
• Shorten or fasten the suction pipe. Use a filter
shield with a check valve.
• Go to a Authorized
Service Center.
The pump is not
working.
The flow rate is too
low.
Not enough pressure.
The pump cannot be
shut off.
• No power.
• Overheating. Water temperature is too high.
• Overheating. Obstructed ventilation slots.
• FI protecting switch is activated.
• Defective motor.
• Water shortage.
• Leaks in the suction line.
• The pump is over the suction line.
• Filter dirty or blocked .
• Blocked check valve .
• Water leak between the motor and the pump,
defective pump shaft.
• Blocked or dirty pump.
• Air in the pump or suction pipe.
• Changes in the water conditions (sand).
• The suction line is grounded.
• The cutting pressure is too high.
• The suction side is not sealed.
Problem
Cause
Solution