3
LIBA-3X21N2
16671
3” x 21”
Class II
IP Grade
IP20
60 Hz
Belt sander
16 AWG x 2C with insulating temperature of 221 °F
1 246 ft/min
1.4 Hp
Code
Description
Belt
Voltage
Frequency
8,3 A
Current
Speed
Power
50 minutes work per 20 minutes idle. Maximum 6 hours per day.
Duty cycle
Conductors
Insulating
Power cord grips used in this product: Type “Y”.
Build quality: Reinforced insulation
Thermal insulation on motor winding: Class E.
120 V~
Technical data
Power requirements
ENGLISH
Tools with double insulation and reinforced insulation eliminate the need of
three parts a grounded third power cord with three prongs or a grounded power connection.
When using an extension cable, verify the gauge is enough for the power that
your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power
loss and overheating. The following table shows the right size to use depending on cable’s length
and the ampere capability shown in the tool’s nameplate. When in doubt use the next higher
gauge.
WARNING
WARNING
WARNING
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 5.9’ to 49.2’ | higher than 49.2’
Ampere
Capacity
Number of
Conductors
Extension gauge
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
When operating power tools outdoors, use a grounded
extension cable labeled “For Outdoors Use”. These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.