![Truper 16539 Manual Download Page 21](http://html1.mh-extra.com/html/truper/16539/16539_manual_1176496021.webp)
• Keep the ventilation slots unobstructed at all times to
guarantee an adequate motor cooling.
• Inspect regularly all the mounting screws. Verify they are
correctly threaded. If a screw is loose, tighten immediate-
ly.
• To clean the tool, use a slightly wet cloth and a drop of
mild detergent. Any other chemical or cleansing agent
may damage the tool parts.
The machine is too hot.
The motor stops
running.
• The work cycle is too long.
• There is not enough water in the pan.
• Blocked ventilation slots.
• The plug is not connected all the way.
• Voltage in the power source is not adequate.
• Tile fragments are obstructing the disc.
• Switch OFF the machine and let it cool down
to room temperature.
• Fill the pan with water.
• Clear the ventilation slots.
• Connect the plug correctly.
• Connect the machine to a power source with
the voltage and frequency specified.
• Switch OFF and disconnect the machine.
Check inside the fixed guard to remove any tile
fragments found.
• Servicing the tool shall only be carried out in a
Authorized Center. Service and
maintenance carried out by non-certified personnel can
be dangerous and could cause personal injury and voids
the product’s Warranty.
When a problem is not solved after verifying the previous
solutions go to a Authorized Service
Center.
9
Troubleshooting
Maintenance
Cleaning and Care
Service
Problem
Cause
Solution
ENGLISH