A
B
3
PRES-1/6T
13498
60 Hz
Water Pressure Booster Pump
3550 RPM
1 A
1/6 Hp
Code
Description
Voltage
Frequency
Current
Speed
Power
Power cord grips: Type “Y”.
Tool Build quality: Basic Insulation
Thermal insulation on motor winding: Class F
Inlet and Outlet Diameter
Maximum Height/Maximum Value
of total Manometer Height
Maximum Inlet Pressure
Liquid Maximum Temperature
50 minutes work per 20 minutes rest. Maximum 6 hours daily
Conductors
Work Cycle
Class I
Insulation
Minimum Inlet Pressure
IP Grade
127 V
176 °F
1/2 NPT
0,05 bar
10 bar
29,5 ft
IP44
ENGLISH
22 AWG x 3C with 221 °F insulation temperature
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
Power requirements
The tool shall be connected to ground while in use to prevent electrical shock.
• Plug in the socket into a properly grounded power outlet as shown in example
A
.
Not all the power outlets are properly grounded. If in doubt, verify with a
qualified electrician.
• If the power outlet is a two-pole (two orifices), BY NO MEANS REMOVE OR
MODIFY THE GROUND CONDUCTOR OF THE PLUG. Use a temporary adapter
as shown in example
B
. Always connect the conductor ring as indicated.
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows the
right size to use depending on cable’s length and the ampere capability shown in
the tool’s nameplate. When in doubt use the next higher gauge
WARNING
CAUTION
CAUTION
When using power tools outdoors, use a grounded extension cable labeled
“Outdoors Use”. These extensions are especially designed for outdoors and reduce the risk of electric shock.
All the cabling, electric connections and the ground connection in the system shall comply
with the
OFFICIAL MEXICAN STANDARD NOM-001-SEDE-2012, ELECTRIC INSTALLATIONS (USE)
or with the local codes and ordinances. Please employ a qualified electrician.
WARNING
WARNING
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 6 ft to 49 ft | higher than 49 ft
Ampere
Capacity
Number of
Conductors
Extension gauge
Technical Data