Power requirements
3
ROU-MN
102315
Class II
60 Hz
Compact Router
18 AWG x 2C with insulation temperature of 221 °F
5.6 A
0.95 HP
Code
Description
Voltage
Frequency
Power
Current
10000 RPM - 30000 RPM
For drills with 1/4” shanks
Speed
Collar clamps
3 1/2”
1 1/8”
Base diameter
1
3
/
8
”
Maximum cutting depth:
Maximum drill diameter
Conductors
Insulation
IP 20
IP Grade
El cable de alimentación tiene sujeta-cables tipo: Y
La clase de construcción de la herramienta es: Aislamiento reforzado.
La clase de aislamiento térmico de los devanados del motor: Clase E
127 V
Technical Data
ENGLISH
Tools with double insulation and reinforced insulation are built with a
polarized plug (one prong is wider than the other) This plug fits in any polarized outlet
and can only be connected one way. If the plug does not fit completely into the outlet,
reverse the plug. If it is not fitting, call a qualified electrician or install a polarized outlet.
Do not alter the plug in any way. Double insulation eliminates the need of a three-prong
grounded power plug or a grounded electric system.
When using an extension cable, make it has sufficient gauge to
carry the current your tool will draw. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
the motor will overheat. The following table shows the right size to use depending on cable’s length and the ampere
capability shown in the tool’s nameplate. When in doubt use the next higher gauge.
WARNING
WARNING
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
18 AWG
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
From 6 ft to 49 ft | Higher than 49 ft
Ampere
Capacity
Number of
Conductors
Extension Gauge
When using power tools outdoors use grounded extension cable labeled “Outdoors
Use”. These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
WARNING
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE