background image

6. WIRING DIAGRAM

ii. Graph Visualization and Data Export

1.  Go to

 

 

2.  Open dashboard as Customer User 

3.  Click on “Export Widget Data” to export in either 

CSV, 

XLS or XLSX 

NETWORK 

STATUS

SEND

RECEIVE

POWER

DI1       DI2       DI3       DI4       DO1       DO2       DO3       DO4

DIGITAL INTERFACES

AI4         AI3        AI2        AI1

ANALOG INTERFACES

TX           RX

RS485

9-36VDC - IN 

80mA MAX

DEVICE 

RESET

COM  DI1  DI2  DI3  DI4  COM

COM  AI4  AI3  AI2  AI1  COM

ANALOG INPUT - 4-20mA

R5485

9-36VDC - OUT

B

A

+

-

- +

GND

AOUT

DOUT1

DOUT2

RS485-A

RS485-B

+V

-V

D

+V

I+

V

-V

VOLTS / FREQ

CURRENT

~

~

PSU

N

L

PSU

Analog 4-20mA

GND/COM

Digital Alarm

EXAMPLE APM

ANTENNA/

ETHERNET

Dependant on 

Model

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for IOT-GATEWAY-ETH

Page 1: ...IOT GATEWAY ETHERNET 4G LTE Quickstart Guide www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...ice Mounting 4 CLOUD ACCESS i Registering a Customer Account ii Adding a New User iii Adding a New Gateway iv Editing Gateway Configuration 5 ALARM SETUP i SMS and Email Setup ii Graph Visualization a...

Page 3: ...Status 4G Gateway Ethernet Gateway NETWORK STATUS 2000ms off 300ms on 300ms off 300ms on No cable connection OFF No cellular network ON Router is initialising Ethernet link established 1000ms off 100...

Page 4: ...ature to router 3 Configure meters to ensure alarms are set APM configurator 4 Plug multi adaptor into router without power 5 Check all wiring connections are correct ii Powering Device 1 Power router...

Page 5: ...vation link to the email address used for the new account See full manual for assigning read only permissions i Registering a Customer User Account 1 Go to 2 Click Sign Up to go to the registration sc...

Page 6: ...ure 4 Change configuration and click save when done iii Adding a New Gateway 1 Go to 2 Open dashboard as Customer User 3 Add unique serial code and model in the add new gateway 4 Device will be claime...

Page 7: ...the cog on the gateway you want to add SMS or email 4 If you leave it blank it will not send SMS or Email 5 If you have made an error when editing the dashboard will tell you that the message is not...

Page 8: ...TAL INTERFACES AI4 AI3 AI2 AI1 ANALOG INTERFACES TX RX RS485 9 36VDC IN 80mA MAX DEVICE RESET COM DI1 DI2 DI3 DI4 COM COM AI4 AI3 AI2 AI1 COM ANALOG INPUT 4 20mA R5485 9 36VDC OUT B A GND AOUT DOUT1 D...

Reviews: