background image

 

Swipe Match-on-Card Family Readers

 

 Installation Manual 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

November 2009 

 

 

 

Models: 
AY-B1663 
AY-B4663 

Summary of Contents for AY-B1663

Page 1: ...Swipe Match on Card Family Readers Installation Manual November 2009 Models AY B1663 AY B4663 ...

Page 2: ...tructions 8 5 Wiring Instructions 10 6 Configuring the Reader 11 6 1 Configuration Procedure 11 7 Testing the Reader 12 8 Modes of Operation 13 8 1 Boot Mode 13 8 2 Configuration Mode 13 8 3 Standby Mode 13 8 4 Read Mode 14 8 4 1 Valid Card Fingerprint Read 14 8 4 2 Invalid Card Fingerprint Read 14 8 5 Lockout Mode 15 Appendix A Limited Warranty 16 Appendix B Technical Support 18 ...

Page 3: ...sor MOC Match On Card technology developed by Rosslare Readers are biometric fingerprint readers that are used with access control systems The Mifare Smart Card Fingerprint Swipe Sensor MOC Reader Family includes the following readers AY B4663 AY B1663 Figure 1 AY B1663 Snail Mifare Smart Card and Fingerprint Swipe ...

Page 4: ... Figure 3 AY B4663 Rambo Mifare Smart Card and Fingerprint Swipe This Installation Manual contains the following information Overview Technical Specifications Mounting Instructions Wiring Instructions Configuring the Reader Testing the Reader Modes of Operation ...

Page 5: ...Products AC 015 AC 115 AC 020 AC 215 AC 225 and AC 525 2 1 Features Mifare Smart Card Fingerprint Swipe Sensor MOC Readers include the following features 3 different designs to accommodate customer requirements and preferences 3 blue LEDs that flash in a pattern that leads users to swipe fingers in the correct direction Designed for indoor use swipe sensor protection required for outdoor use Suppo...

Page 6: ...iegand 32 Wiegand 34 Wiegand 40 Read Range max 4 cm 1 6 inches Electrical Characteristics Power Supply Type Linear type recommended Input Voltage 5 16VDC Absolute Maximum non operating 18VDC Maximum Input Current Standby 85 mA 12VDC Read 300 mA 12VDC Tamper Output Open collector active low max sink current 32mA Maximum Controller Cable Distance 150 m 500 ft using 18AWG shielded cable Frequency 13 ...

Page 7: ...ating Temp Range 25 C to 60 C 13 F to 140 F Storage Temp Range 40 C to 85 C 40 F to 140 F Operating Humidity 5 95 non condensing Dimensions Reader Height x Width x Depth Weight AY B1663 85 4 x 50 6 x 27 mm 3 36 x 1 99 x 1 06 inch 65 g 2 3 oz AY B4663 70 1 x 54 1 x 39 1 mm 2 76 x 2 13 x 1 54 inch 90 g 3 2 oz ...

Page 8: ...ted outside To mount the Reader 1 Determine an approximate surface location for the Reader 2 Peel off the back of the self adhesive mounting label template and place it on the required mounting location 3 Using the template as a guide drill two holes of the size indicated on the template on the surface to mount the Reader 4 Insert a suitable wall plug into each hole 5 Drill a 7 16 10 mm hole for t...

Page 9: ...B4663 Figure 5 Removing the Top Cover 8 Route the interface cable from the Reader to the Controller Note The Reader can also be mounted using strong epoxy glue After application firmly hold the Reader in place until the glue dries 9 Carefully re attach the snap off front cover of the Reader and secure the case security screw at the bottom using the security hex key ...

Page 10: ...ilized connect the purple wire to the correct input on the Controller 5 Trim and cover all conductors that are not used Table 1 Wiring the Reader to the Controller Color Wiring Black Shield Ground Red Vin Green Data 0 White Data 1 Brown LED control Orange Buzzer control Purple Tamper Note The individual wires extending from the Reader are color coded according to the required Wiegand standard When...

Page 11: ...he AS B01 SW manual for more details 6 1 Configuration Procedure It is recommended to configure the Reader one time only immediately following installation To configure the Reader 1 Power up the Reader The middle LED lights continuously for 8 seconds of boot loading Then 3 long beeps are generated and all 3 LEDs flash simultaneously for 3 seconds The Reader is in Configuration mode 2 Within 30 sec...

Page 12: ...Present the appropriate type of card to the Reader If the card is valid and contains a fingerprint template a short confirmation beep is generated and all 3 LEDs will flash indicating successful read 3 Following the confirmation the LEDs will turn on and off in a fast circular mode swipe your finger on the swipe sensor If the fingerprint matches the template on the card three short confirmation be...

Page 13: ...is lit and firmware upgrades can be performed 8 2 Configuration Mode After the Boot mode ends the unit LEDs all 3 will flash simultaneously 3 times for the duration of 3 seconds at a rate of 600on 600off 600on 600off 600on ms indicating that the unit is in configuration mode Configuration mode last for 30 seconds following the boot mode Note The Master card is configured using the Desktop Reader C...

Page 14: ...eep 50 milliseconds is generated and the LEDs will indicate a success flash followed by all 3 LEDs flashing in a fast circular motion indicating that the reader is waiting for the fingerprint swipe 3 Swipe your fingerprint onto the fingerprint reader When a match is found short beep 50 milliseconds is generated and the LEDs will indicate a success flash Note If the user does not swipe their finger...

Page 15: ... mode If there are fewer than 5 invalid card fingerprint reads within 30 seconds the Reader enters Standby mode Note When connected and operating with Rosslare s controllers and the AxTrax software the readers send specific messages when failures occur Those messages appear and can be handled on the AxTrax software Fingerprint data reading from card failed Swipe sensor Fingerprint reading failed F...

Page 16: ...nce with the terms of this warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may...

Page 17: ... with the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslar...

Page 18: ...osslaresecurity com United States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martine...

Page 19: ......

Page 20: ...0706 0960334 00 www rosslaresecurity com ...