Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must.

lsvr-manual-annexure-4

www.trumen.in

Annexure-4

Electrical Connections - 

LSVR-AR (EIAR)

electrical connections (AC)

Page 3

x

dry delay
wet delay

to set

turn-on

LSVR-AR

5 sec

alarm

normal

18... 260V AC

1 2 3 4 5 6 7 8 9

ON

min failsafe

2 wire AC series Relay
(<5mA holding current)

x

dry delay
wet delay

to set

turn-on

LSVR-AR

5 sec

alarm

normal

18... 260V AC

1 2 3 4 5 6 7 8 9

ON

min failsafe

2 wire AC series Relay
(<5mA holding current)

Not Used

L

N

AC Supply

18 to 260 VAC

Specified AC Series Relay

Use AC relay / contactor having maximum 150mA to 
magnetize and holding current should not be less than 4mA.
Voltage rating of AC relay should be as per input supply voltage.

Summary of Contents for LSVR Series

Page 1: ...39 Mangal Nagar Behind Sai Ram Plaza Near Rajiv Gandhi Circle AB Road Indore MP 452 001 India Phone 91 731 497 2065 Trumen Technologies Pvt Ltd Customer Support Phone 91 731 656 2425 email sales trume...

Page 2: ...LSVR DP EIDP ERDP Page1 Annexure 2 Page1 Page2 Page3 Introduction LSVR U S P Order code EIUSP ERUSP controls indicators connection terminals configuration switches Electrical Connections LSVR U S P E...

Page 3: ...LSVR excites the piezo electric crystals inside the tuning rod which makes the rod vibrate at it s natural resonance frequency in free air Amplitudes of vibration are above threshold when the rod is f...

Page 4: ...hort Circuit Safe Integral Remote Electronics SPDT PNP Output Universal Supply for SPDT Output 15 to 80 VDC 15 to 260 VAC 50 60Hz DC Supply for PNP Output 15 to 60 VDC Potential Free DPDT Relay Output...

Page 5: ...per tank 6 Vibrating rod probe 6 1 Should never be bent 6 2 Should never be held from thin part 6 3 Should never be cut or machined in any way 6 4 Should never be extended by welding or machining 7 Ca...

Page 6: ...on turn switch 2 3 ON Time delay solves switching issues in agitated materials Device shows no material after some time even when rod is inside the material Material fluffy or rod rate holes the mater...

Page 7: ...ons 1 of DC or Live of AC Supply input 2 of DC or Neutral of AC Supply input Supply 15 to 80VDC or 15 to 260VAC 50 60Hz 3 Earth terminal for safety 4 Normally connected terminal of contact 1 5 Common...

Page 8: ...o power failure No material at low level Switch no 4 is on failsafe low minimum Indicating alarm status 4 5 6 7 8 9 Relay OFF alarm contacts 4 5 6 7 8 9 1 2 3 4 ON min failsafe Indicating alarm status...

Page 9: ...er L1 N U 15 80V DC 15 260V AC 1 2 3 4 5 6 7 8 9 ON output contact 1 output contact 2 Live Neutral 15 to 260 VAC 50 60 Hz sensitive dry delay wet delay min failsafe to set turn on LSVR UD status power...

Page 10: ...erflow detection max failsafe configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 of DC Supply input 2 of DC Supply input Supply 12 to 60VDC 3 Earth terminal fo...

Page 11: ...failsafe low minimum Indicating alarm status 1 2 3 4 ON min failsafe Indicating alarm status Material is above the low level or rod is covered with material 1 2 3 4 ON min failsafe Material is above t...

Page 12: ...afe to set turn on LSVR DP 5 sec status power U 12 to 60V DC 1 2 3 4 5 6 7 8 9 PNP alarm oat output unused terminals DC 12 to 60 VDC ON Electrical Connections LSVR DP EIDP ERDP Annexure 2 1 2 3 Red Wh...

Page 13: ...of AC Supply input 2 of DC or Neutral of AC Supply input Supply 15 to 80VDC or 15 to 260VAC 50 60Hz 3 Earth terminal for safety 4 Normally connected terminal of SPDT contact 5 Common terminal of SPDT...

Page 14: ...covered with material Indicating alarm status No material at low level Switch no 4 is on failsafe low minimum Indicating alarm status Material is above the low level or rod is covered with material 1...

Page 15: ...0V AC 1 2 3 4 5 6 7 8 9 ON U 15 60V DC PNP o p less than 60VDC only PNP output DC 15 to 60 VDC output contact sensitive dry delay wet delay min failsafe to set turn on LSVR U S P 5 Sec status power L1...

Page 16: ...witch in On and Off Positions 1 Live of AC Supply through fuse 2 Neutral of AC Supply input through specified series relay 18 to 260VAC 50 60 Hz series 3 Earth terminal for safety 4 5 6 7 8 9 Not used...

Page 17: ...od is dipped in material at high switch point When switch no 4 is on failsafe low minimum output status shows alarm when there is no material at low switch point or rod is out of the material When swi...

Page 18: ...18 260V AC 1 2 3 4 5 6 7 8 9 ON min failsafe 2 wire AC series Relay 5mA holding current x dry delay wet delay to set turn on LSVR AR 5 sec alarm normal U 18 260V AC 1 2 3 4 5 6 7 8 9 ON min failsafe 2...

Page 19: ...ection max failsafe configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 of DC Supply input 2 of DC Supply input DC Supply 12 to 60VDC 3 Earth terminal for safet...

Page 20: ...l at high switch point or rod is out of the material When switch no 4 is off failsafe high maximum output status shows alarm if rod is dipped in material at high switch point When switch no 4 is on fa...

Page 21: ...xure 5 Not used 1 2 3 4 5 6 7 8 9 sensitive dry delay wet delay min failsafe to set turn on LSVR DL 8 16 5 sec alarm power U 12 to 60V DC ON Loop powered 8mA 1mA alarm 16mA 1mA normal sensitive dry de...

Reviews: