10
Technical Data
Power supply
AC voltage 230 V ~, 50 Hz, single-phase
12 V input
DC voltage 12 V from the battery
Output voltage
DC voltage 12 V
Output
PS 100 Automatic 100 VA (W), continuous operation
PS 200 Automatic 200 VA (W), continuous operation
Ambient temperature
-20 °C to +35 °C
Configuration
In accordance with the VDE provisions and the device
safety law
Dimensions / weight
Casing
Aluminum, ventilated
Length
200 mm
Width
160 mm
Height
PS 100 (200) Automatic 100 (142) kg
Weight
PS 100 (200) Automatic 2.5 (4.6) kg
The right to effect technical modifications is reserved!
Troubleshooting
Error
Rectification
The 12 V output
is not supplied
with power
when in mains
supply mode.
Check that the device plug is securely
inserted into the mains socket.
Press the push button of the 230 V circuit
breaker.
Ensure that the device is well ventilated.
Ensure that the ventilation slits on the
device are not blocked.
The device may become too warm when
overloaded in mains supply mode. The
power drawn must not exceed the output
power of the device.
The 12 V output
is not supplied
with power
when in battery
mode.
Test the 20 A fuse on the battery and
replace if necessary.
Check that the flat plugs and the cables
on the 12 V input are connected tightly.
Check the battery voltage and charge the
battery if necessary.
Short-circuit on
the 12 V output
(consumer).
Disconnect the cable on the 12 V output
and remedy the short-circuit.
Test the 20 A fuse on the battery in bat-
tery mode and replace if necessary.
Press the push button of the 230 V circuit
breaker in mains supply mode.
If these measures do not solve the problem, please
contact the Truma Service Centre.