9
Fresh water tank
The supplied sensor
is designed for tank
heights of 150 mm to 380 mm
external dimensions and for
vertical installation.
3/4
1/4
1/2
1/1
br
ws
gn
ge, gr
gn
br
ge
gr
ws
Establish the height of the
tank (external dimensions).
Drill the borehole with a
diameter of 38 ± 0.5 mm
at the highest point close
to the middle of the tank
and the cleaning opening.
If necessary, shorten the
measuring rods (see short-
ening table).
Insert the sensor into the
cleaning opening and
screw tight – observe the
correct position of the
sealing ring.
Tighten the nuts by hand.
Shortening table
Tank height
External
dimensions
[mm]
Measuring rod length [mm]
ws
br
gn
ge, gr
380
Original length
370
22
81
170
260
360
22
78
165
253
350
22
76
160
245
340
22
73
155
238
330
22
71
150
230
320
22
68
145
223
310
22
66
140
215
300
22
63
135
208
290
22
61
130
200
280
22
58
125
193
270
22
56
120
185
260
22
53
115
178
250
22
51
110
170
240
22
48
105
163
230
22
46
100
155
220
22
45
95
148
210
22
44
90
140
200
22
43
85
133
190
22
41
80
125
180
22
39
75
118
170
22
38
70
110
160
22
36
65
103
150
22
35
60
95
The table applies for symmetrically shaped tanks.
The volume of non-symmetrical tanks needs to be
determined.
–
–
–
–
–
Connection
Before connecting or disconnecting the cables, the
supply lines to the battery and mains supply must be
disconnected! Only use the specified cable cross-sections
and fuses of the correct strength!
Install the cables to the tanks and battery II.
Connect the sensors and battery II to the panel. The plug con-
nectors can only be inserted to the correct connection when
they are in the right position.
Ensure that all the catches lock into place.