Truma Combi 6 Operating Instructions Manual Download Page 4

4

Operating instructions

Always observe the operating instructions and “Impor-
tant operating notes” prior to starting! 

The vehicle owner 

is responsible for the correct operation of the appliance.

The installer or vehicle owner must apply the yellow sticker 
with the warning information, which is enclosed with the 
 appliance, to a place in the vehicle where it is clearly visible to 
all users (e.g. on the wardrobe door)! Ask Truma to send you 
stickers, if necessary.

Before using for the first time, it is essential to flush the 
entire water supply system through with clean water. If 

the heater is not being used, always drain the water contents 
if there is a risk of frost! 

There shall be no claims under 

guarantee for damage caused by frost!

Materials in the device which come into contact with 
water are suitable for use with drinking water (see 

manufacturer declaration: www.truma.com – Downloads – 
Manufacturer Declaration).

Control panel

1

3

5

7

9

60

°

Combi

1

2

3

4

5

60

°

c

d

f

b

a

g, h

e

a  = Rotary switch for room temperature (1 – 5)
b = green LED lit “Operation” 

green LED blinking 
“after-running” is active in order to reduce the unit’s 
temperature 

c  = Summer operation (water temperature 60 °C)
d = Winter operation 

(heating 

without

 water temperature monitoring 

or with drained water system)

e = Winter operation 

(heating 

with

 water temperature monitoring)

f  = Rotary “Off” switch
g = yellow LED lit “Boiler heat-up phase”
    yellow LED flashes “failure”
h = red LED lit, red LED blinking “failure”

The LEDs are visible only when the unit is switched on.

Room thermostat

To measure the room temperature, an external room tem-
perature sensor (i) is located in the vehicle. The location of the 
sensor is determined individually by the vehicle manufacturer, 
depending on the vehicle type; consult the operating instruc-
tions for your vehicle for further details.

i

i = Room temperature sensor

The thermostat setting on the control panel (1 – 5) must be 
determined individually depending on the heating requirement 
and the type of vehicle. For an average room temperature of 
about 23 °C, we recommend a thermostat setting of about 4.

Initial start-up

(or when the fuel tank has run empty)

Filling the fuel lines

The heater normally has to be started up several times to fill 
the fuel lines.

Connect unit to control panel to do this. The unit automatically 
performs 2 start attempts (initial start and repeat) per switch-
on procedure with a run time of 2 minutes in each case. If no 
flame is detected after the repeat start, the unit switches to 
fault and has to be switched off and on again at the control 
panel. 

After a total of 15 unsuccessful starting attempts (initial 
and repeat start) without forming a flame, the equipment 

is blocked. To remove the block, please contact the Dometic 
Service Centre (see Service Booklet or www.truma.com).

Check fuel lines and connections for leaks after filling the 
fuel lines. 

Taking into operation

Heating operation is basically possible without 
restriction with or without water content.

Check to make sure the cowl is unobstructed. Remove any 
covers that may be present.

Summer operation

(boiler operation only)

Move the rotary switch on the control panel to position (c – 
summer operation) 60 °C. The green (b) and yellow (g) LEDs 
light up.

After reaching the set water temperature (60 °C), the burner 
will switch off and the yellow LED (g) will be extinguished.

Winter operation

– Heating 

with

 water temperature monitoring

Set the rotary switch to the operational setting “e”.

Set the rotary switch (a) to the desired thermostat setting 
(1 – 5). The green LED (b) for operation is lit and simulta-
neously indicates the position of the selected room tem-
perature. The yellow LED (g) indicates the water‘s heat-up 
phase.

The unit automatically selects the required power level ac-
cording to the temperature difference between the setting 
on the control panel and the current room temperature. 
Once the room temperature set on the control panel has 
been reached, the burner switches back to the lowest stage, 
and heats the water content to 60 °C. The yellow LED (g) 
will be extinguished after the water temperature is reached.

The warm air fan can continue to run in order to cool the 
unit (after-run).

– Heating 

without

 water temperature monitoring

Set the rotary switch to the operational setting “d”.

Turn the rotary switch (a) to the desired thermostat setting 
(1 – 5). The green LED (b) for operation is lit and simultane-
ously indicates the position of the selected room tempera-
ture. The yellow LED (g – water‘s heat-up phase) will be lit 
only when the water temperature is below 5 °C!

Summary of Contents for Combi 6

Page 1: ...Comfort on the move 1 3 5 7 9 60 Combi 1 2 3 4 5 60 Combi D 6 Australia Operating instructions Page 2 To be kept in the vehicle...

Page 2: ...mperature dif ference between the temperature set on the control panel and the current room temperature When the boiler is filled the water is automatically heated as well The water tem perature depen...

Page 3: ...placed near or directly beneath an open ing window the device must be equipped with an automatic shut off device in order to prevent operation with the window open The exhaust gas double duct exhaust...

Page 4: ...heater normally has to be started up several times to fill the fuel lines Connect unit to control panel to do this The unit automatically performs 2 start attempts initial start and repeat per switch...

Page 5: ...heck that the drain valve in the cold water intake is closed Lever should be in horizontal position position k m k k k Lever position Closed m Lever position Drain Switch on the power for the water pu...

Page 6: ...els 2000 4000 6000 W Fuel consumption 220 630 ml h in regular operation between Off and lowest operating level less than 190 ml h Air delivery volume free blowing without hot air pipe max 287 m h Curr...

Page 7: ...hes except 6 times or red LED shines Malfunction of the heating device Please contact the Dometic Service Yellow LED flashes 1 x Possible under voltage 11 5 V Use the electrical power from the battery...

Page 8: ...ction of safety drain valve Water pressure too high Check pump pressure max 400 kPa If connected to a central water supply rural or urban connection a pressure reducer must be used which will prevent...

Page 9: ...warranty you should contact Dometic Pty Ltd Whilst this book represents service outlets at the time of printing changes occur from time to time Should you have any queries or wish to locate your neare...

Page 10: ......