Fault
Cause
Remedy
Gas mode
Boiler does not operate after
switching on.
– No 12 V
power supply
– Window open
– Check battery voltage (min. operating voltage 10.5 V).
– Check boiler fuse
(see Maintenance, “Fuses”).
– Close window above cowl.
After switching on, boiler does
not operate and red LED comes
on after about 30 sec.
After a long period of operation,
boiler switches to “Fault” and
red LED comes on.
– Cowl cover is fitted
– No gas supply
– Incorrect gas pressure
– Air in gas supply
– Overtemperature sensor
has activated
– Remove cowl cover and/or check for soiling and remove
if necessary.
– Check gas valves and cylinder.
– Check gas valves and cylinder.
– To clear the fault (and bleed off air), switch the appliance
off, wait for 5 minutes and switch it on again.
– Check the water content, topping up if necessary (close
drain valve).
– To clear the fault, switch the appliance off, wait for 5 min-
utes and switch it on again.
Water supply
Water dripping from drain
valve.
Warm water coming out of cold
water tap.
– Water pressure too high
– Hot water flowing
back into cold water supply
– Check water pressure (max. 2.8 bar). When connecting to
a central water supply a pressure reducer must be used.
– Fit a non-return valve to the cold water supply
(see installation instructions, “Water connection”).
If these actions do not remedy the problem, please contact Truma Service.
Troubleshooting guide
14
Summary of Contents for BGF
Page 51: ......