7
Technical data
Power supply
230 V – 240 V~, 50 Hz
Current consumption
Cooling: 4.2 A
Heating: 3.7 A
Start-up current
28 A (150 ms)
Cooling power
2.4 kW
Heating power
1.7 kW (heat pump)
Volumetric air flow
Max. 400 m³/h
Operational limits
+4 °C to 40 °C
Maximum tilt during operation
8 %
Weight
33.5 kg plus installation materials
Dimensions (W x H x D)
External: 660 x 248 x 1008 mm
Internal: 523 x 46 x 670 mm
Refrigerant
R 407C
Refrigerant content
See type plate on unit
N4213
Installation dimensions
(dimensions in mm)
670
1008
248
46
25 -
110
400
(380)
400
(350)
523
195
(215)
530
660
Accessories
Filter set, 2 x (part no. 40091-16800)
10 mm roof thickness adapter, 1 x (part no. 40091-16900)
Sealing frame (part no. 40091-19500)
recommended for optimum sealing in the case of retrofitting
in vehicles with cut-outs measuring 400 x 400 mm.
Troubleshooting
Fault
Cause / Action
Unit not cooling
Thawing process in progress
The temperature set on the re-
mote control has been reached
or is too high
–
–
Unit not heating
Thawing process in progress
(outside temperature between
4 °C and 7 °C)
Outside temperature below 4 °C
–
–
Unit underperforming
or failing in cooling /
heating mode
Filter soiled, replace filter
Air ways to the outside soiled /
blocked
–
–
Moisture on the un-
derside of the air
distributor
Close windows and doors and
set the fan level to high
–
Water dripping out of
air distributor
Condensation trap on external
unit blocked
No proper seal between unit
and roof (e.g. faulty seal)
Angle of tilt of system too great
–
–
–
Remote control not
working
Check remote control batteries
and replace if necessary
–
Unit not responding
to remote control
commands
Check for obstructions between
remote control and IR receiver
–
Should these actions not resolve the corresponding
problem, please contact Dometic Service.