This device complies with part 15 of the FCC Rules. Operation is subject 
to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
     interference that my cause undesired operation.
This equipment has been tested and found to comply with the limits for 
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
 
This equipment generates, uses and can radiate radio frequency energy.
However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference 
to radio or reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced technician for help.
MODIFICATION:
Any changes or modifications not expressly approved by the grantee of 
this device could void the user’s authority to operate the device.

FCC ID: 2ABG7-TBG-460

Summary of Contents for TBG-460

Page 1: ...Blood Glucose Cholesterol 2 in 1 Monitoring System User s Manual 2015 07 14 Rev 01 www trulyinstrument com Model TBG 460GC...

Page 2: ...Testing 3 2 Connect iOS device via Bluetooth 3 3 Perform the Blood Glucose Test 3 5 Special messages 3 6 Care after the test Chapter 4 Chapter 5 Meter Memory Function Chapter 6 Installing Replacing th...

Page 3: ...ugh the operation procedures with illustrated directions and help you find the required informations Please contact the local distributor for questions and enquiries WARNING Please carefully read the...

Page 4: ...t Hct above 55 may cause reduced glucose results versus a whole blood reference Do not drop the product Keep the lancets and lancing device out of the reach of the children o Keep the meter and test s...

Page 5: ...companying documents Storage temperature limitation Use by EU Representative Catalogue number Product number Manufactured by 0123 1 5 System Components Test Strip Port Insert test strip here The meter...

Page 6: ...At least 10uL of blood sample is essential Reaction Zone Reaction zone of Total Cholesterol CHOL Glucose Test Strip Blue Color Sample Inlet The inlet where the whole blood or control solution is drawn...

Page 7: ...s are listed as follows Set the Year 1 When the meter enter setting mode the first item on the screen such as 2012 will blink on screen which means Year 2 Press the up down button to 3 After you set t...

Page 8: ...wm button until the correct measurement unit appears 2 Press the memory button will show OFF on the screen and power off Chapter 3 How to perform Test 3 1 Before Testing 7 Coding the Meter TRULY TRULY...

Page 9: ...so the same as marked on the test vial Remove the code strip should appear on the screen indicating that the meter has been successfully coded Cautions If E E appears on the screen during coding proce...

Page 10: ...napping it back onto the lancing device body 4 Select the skin penetration depth by turning the depth selector until the desired number can be seen in the selection window 5 levels of skin penetration...

Page 11: ...Be careful to make sure the marked re code test mode and code number on the screen are the same as the one on the test strip vial Icon GLUC and CHOL indicate measuring mode of glucose and total chole...

Page 12: ...wn from 26 seconds for cholesterol testing 3 4 Perform the Total Cholesterol Test 11 4 Touch the sample Inlet of the strip to the drop of blood sample until the meter sounds a beep which means the sam...

Page 13: ...s 3 6 Care after the Test Directions 1 Improper usage of the meter such as dropping bumping or other violent impact may cause the meter damaged 2 Please keep meter away by interferences of magnetic el...

Page 14: ...o keep the strips in dry condition 2 Be careful to make sure the test mode and code number on the screen are the same as the one marked on the test strip vial If not remove the test strip and re code...

Page 15: ...est mode only total cholesterol test mode do not have the day average function Chapter 5 Meter Memory Function Please read this user s manual for control solution test carefully before use Do not reus...

Page 16: ...l hear a beep sound which indicates that meter is 3 Place back the cover onto the meter ready 5 After the 28day average the latest stored result M01 appears on the screen Then you can read the stored...

Page 17: ...bent hole Revlew the instructiona and try again with a new test strip If the problem persists please contact the dealer for service E 9 Chapter 7 Storage and Handling of Meter and Strips Due to sensit...

Page 18: ...ter and the test strip have reached at temperature within the operating range E U It could be caused by a used test strip or a temporary or permanent electronic problem Repeat the test with a new test...

Page 19: ...se level 75 mg dL 4 17mmol L 20 at Total Cholesterol 150mg dL 3 88mmol L Electrochemical Biosensor Plasma equivalent Glucose 20 600 mg dL 1 1 33 3 mmol L Total Cholesterol 100 400 mg dL 2 59 10 35 mmo...

Page 20: ...radio frequency energy However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or reception which can be...